E15 drives

Type plate
Type designation: e.g. R 30-17-E15
R
Size of drive
(tube diameter)
R - 45 mm
L - 58 mm
30-17
Rated torque/output speed
E
Electronic limit switch
15
Consecutive number
Operating mode (short-period operation
S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g. 17 01 12504
17
Year 2017
01
Calendar week
12504 Consecutive number
Wiring
Two or more drives with electronic limit switching
can be connected in parallel to a control point.
The maximum number of synchronously con-
trolled drives depends on the load capacity of
the operator control.
The following applies to operator controls with
a 5A contact load rating:
R8-17-E15 to R12-17-E15 =
max. 5 drives
R20-17-E15 to R60-17-E15 =
max. 3 drives
L70-17-E15 to L120-11-E15 =
max. 2 drives
The changeover time for switching the running
direction must be at least 0.5 seconds. The
switch and controls must not execute simulta-
neous retract and extend commands.
Drive
Drive 1
Drive 2
88
Mains
Mains