M (M04) drives

Type plate
Type designation: e.g. R 8/17 C M
R
Size of drive
(tube diameter)
P - 35 mm
R - 45 mm
L - 58 mm
8/17
Rated torque/output speed
C
Pluggable connecting cable
M
Mechanical limit switching
Operating mode (short-period operation
S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g. 08 40 961630
08
Year 2008
40
Calendar week
961630 Consecutive number
Wiring
Drives with mechanical limit switching must
not be connected in parallel to a control point.
Discharge of the capacitor could damage
the limit switches. This would cause the limit
positions to be "overrun".
The changeover time for switching the
running direction must be at least 0.5 seconds.
The switch and controls must not execute
simultaneous retract and extend commands.
Drive
Drive 1
Drive 2
76