C01 drives

Type plate
Type designation: e.g. R8-C01
R
Size of drive
(tube diameter)
P - 35 mm
R - 45 mm
8
Rated torque
C
Centronic remote control
01
Consecutive number
Operating mode (short-period operation
S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g. 15 07 91500
15
Year 2015
07
Calendar week
91500 Consecutive number
Wiring
Drives with electronic limit switching and inte-
grated radio receiver are connected directly to
the power supply. The brown wire and the blue
wire together are connected to the neutral wire.
For the sensitive obstacle detection to be
active, the drive adapter with object detection
must be mounted on the drive.
Drive adapter
58
Drive
Mains
Drive adapter with
obstacle detection