Type plate
Type designation: e.g. R8-E01
R
Size of drive
(tube diameter)
P - 35 mm
R - 45 mm
8
Rated torque
E
Electronic limit switch
01
Consecutive number
Operating mode (short-period operation
S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g. 15 06 61007
15
Year 2015
06
Calendar week
61007 Consecutive number
Wiring
Two or more drives with electronic limit switch-
ing can be connected in parallel to a control
point. The maximum number of synchronously
controlled drives depends on the respective
current consumption but must not exceed 5.
The changeover time for switching the running
direction must be at least 0.5 seconds.
The switch and controls must not execute
simultaneous UP and DOWN commands.
For the sensitive obstacle detection to be
active, the drive adapter with object detection
must be mounted on the drive.
Drive 1
Drive 2
Drive adapter
44
Mains
Drive adapter with
obstacle detection