Sef I1 Drives - Becker M Installation Manual

Drives and control units for roller shutters and sun protection systems
Table of Contents

Advertisement

SEF I1 drives

Type plate
Type designation: e.g. R8/17C SEF I1
R
Size of drive
(tube diameter)
P - 35 mm
R - 45 mm
L - 58 mm
8/17
Rated torque/output speed
C
Pluggable connecting cable
S
Electronic limit switching for sun
protection
E
Automatic reversing in the lower
limit position
F
Radio receiver
I1
Programmable for different lock-
ing systems
Operating mode (short-period opera-
tion S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g. 13 39 51682
13
Year 2013
39
Calendar week
51682 Consecutive number
Wiring
Drives with electronic limit switching and inte-
grated radio receiver are connected directly
to the power supply. The brown wire and the
blue wire together are connected to the neu-
tral wire.