Table of contents General .................................... 3 Warranty ..................................... 3 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 5 Assembling and disassembling the plug-in connecting cable.................... 6 Assembly .................................... 6 Setting the limit positions with the switches on the drive head .................... 9 Deleting the limit positions using the switches ........................
General These tubular drives are high-quality products with the following features: • Optimised for roller shutter operation • Installation without stops possible (from lower point to upper point) • Automatic detection of the lower limit position when using springs in conjunction with the "drive adapter for obstacle detec- tion"...
Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. Instructions for the user General information • The drive must be disconnected from its power source during cleaning and maintenance and when re- placing parts.
• If the drive is used for shading solutions in a specially marked area (e.g., escape routes, hazard zones, safety areas), compliance with all applicable regulations and standards must be ensured. • Once the drive has been installed, the fitter must mark the used tubular drive in the “Technical data” chapter and make a note of the installation position.
Assembling and disassembling the plug-in connecting cable Caution The power supply to the connecting cable must be disconnected prior to assembly/disas- sembly. Assembling the plug-in connecting cable Ø35/Ø45/Ø58 Insert the dead connecting cable into the drive head until the locating lug clicks into place in the drive. If necessary, use a suitable flathead screwdriver to assist with insertion.
Page 7
Caution Electrical connections may only be carried out by a qualified electrician. Prior to assembly, the power supply must be disconnected and secured. Please give the enclosed connection information to the responsible electrical contractor. Calculate the space required at the side (M) by measuring the drive head (1) and wall bracket (2). The clear dimension of the box (X) minus the space required at the side (M) and idler (G) gives the length (L) of the barrel: L=X-M-G.
Page 8
Mounting the drive in the tube For profile shafts: In the case of some drive adapters, tolerances of the groove widths in different barrels can be offset by rotating the drive adapter into a different groove recess. These groove recesses have different sizes and allow the drive to fit exactly.
Setting the limit positions with the switches on the drive head Attention The cord switch set is only designed for the commissioning, and not for continuous opera- tion. Programming setting Switch Delete setting Direction arrows Connect the pigtail wires of the tubular drive to those of the same colour in the cord switch set or operator control and switch on the power supply.
Page 10
Upper stop to lower stop Set both switches to the delete setting. Execute a short drive command. Set both switches to the programming setting. Open to the permanent upper stop until the tubular drive switches off automatically. Then close to the permanent lower stop without pausing. During travel, the end posi- tion status indicator (ESI) must be displayed before the end position is reached.
Upper point to lower stop There is no shading solution length adjustment with this limit position setting. Set both switches to the delete setting. Execute a short drive command. Open to the desired upper limit position. Now reset the switch of the UP direction of rotation from the delete setting to the pro- gramming setting.
Setting the limit positions using the programming unit Programming setting Switch Delete setting Direction arrows Connect the wires of the tubular drive to those of the same col- our in the programming unit for drives with electronic limit Programming button Travel button switching and switch on the power supply.
Page 13
Upper stop to lower stop Set both switches to the programming setting. Open as far as the permanent upper stop. ▻ The tubular drive switches off automatically. Then close to the permanent lower stop without pausing. During travel, the end posi- tion status indicator (ESI) must be displayed before the end position is reached.
Page 14
Upper stop to lower point Set both switches to the programming setting. Open as far as the permanent upper stop. ▻ The tubular drive switches off automatically. Then close to the desired lower limit position. Press the programming button of the programming unit for 3 seconds. ▻...
Deleting the limit positions using the programming unit Connect the wires of the tubular drive to those of the same colour in the programming unit and switch on the power supply. Please pause for 1 sec after the last drive command before beginning the deletion se- quence.
Deleting both limit positions Open/close the shading solution to a point between the limit positions. Press the programming button and keep it pressed. Then press down the travel button and keep it pressed. Now release the programming button, but continue to keep the travel button pressed. Next press the programming button again.
Page 17
Upper stop to lower stop Set both switches to the programming setting. Open to the permanent upper stop. ▻ The tubular drive switches off automatically. Then close to the permanent lower stop without pausing. During travel, the end posi- tion status indicator (ESI) must be displayed before the end position is reached. ▻...
Upper point to lower point There is no shading solution length adjustment with this limit position setting. Set both switches to the programming setting. Open to the desired upper limit position. Carry out the following sequence without interruption between the individual drive commands. ▻...
Additional upper anti-freeze mechanism The upper anti-freeze mechanism helps to prevent the roller shutter from freezing in the upper limit position, as the roller shutter stops just before the upper stop. The distance from the upper stop is automatically cyclically checked and, if necessary, correc- ted.
Fly screen protection function If the fly screen protection function is activated, obstacle detection is activated after a revolution of the barrel of approx. 140° from the upper limit position. If the roller shutter curtain meets an opened fly screen door, the drive stops and returns to the upper limit position.
Technical data dia. 35 Tubular drive P5-16 P9-16 Model Type CPRO+ Rated torque [Nm] Output speed [rpm] Limit switch range 64 revolutions Supply voltage 230 V AC / 50 Hz Connected load [W] Rated current consumption [A] 0.36 0.47 Mode S2 4 min Degree of protection IP 44...
What to do if...? Problem Remedy The roller shutter curtain is raised unevenly or not at all. Stops have broken off or one or several attachments are broken. Repair system; delete limit positions, then reprogram limit positions. Tubular drive overruns the limit position or does not reach the Repair system;...
Sample wiring diagrams The assignment of the black and brown wires according to the direction of travel is de- pendant on how the drive is installed (mounted to the right or to the left). Controlling one/several drive(s) via a single switch/button Central, group and individual control using Centronic UnitControl UC42 Central Control unit...