E03 Drives - Becker M Installation Manual

Drives and control units for roller shutters and sun protection systems
Table of Contents

Advertisement

E03 drives

Type plate
Type designation: e.g. R8-E03
R
Size of drive
(tube diameter)
P - 35 mm
R - 45 mm
8
Rated torque
E
Electronic limit switch
03
Consecutive number
Operating mode (short-period operation
S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g. 15 06 91505
15
Year 2015
06
Calendar week
91505 Consecutive number
Wiring
Two or more drives with electronic limit switch-
ing can be connected in parallel to a control
point. The maximum number of synchronously
controlled drives depends on the respective
current consumption but must not exceed 5.
The changeover time for switching the
running direction must be at least 0.5 seconds.
The switch and controls must not execute
simultaneous UP and DOWN commands.
Drive
Drive 1
Drive 2
30
Mains
Mains

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents