PR+ drives

Type plate
Type designation: e.g. R 8/17 C PR+
R
Size of drive
(tube diameter)
P - 35 mm
R - 45 mm
8/17
Rated torque/output speed
C
Pluggable connecting cable
P
Point to point programming pos-
sible
R
Electronic limit switching for roller
shutters
+
Suitable for anti-lifting device
Operating mode (short-period operation
S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g. 08 40 961630
08
Year 2008
40
Calendar week
961630 Consecutive number
Wiring
Two or more drives with electronic limit switch-
ing can be connected in parallel to a control
point. The maximum number of synchronously
controlled drives depends on the respective
current consumption but must not exceed 5.
The changeover time for switching the
running direction must be at least 0.5 seconds.
The switch and controls must not execute
simultaneous UP and DOWN commands.