Model: E01 Assembly and Operating Instructions Tubular drives for roller shutters Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference. Becker-Antriebe GmbH Friedrich-Ebert-Straße 2-4 35764 Sinn/Germany www.becker-antriebe.com...
Table of contents General .................................... 3 Warranty ..................................... 3 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 6 Assembling and disassembling the plug-in connecting cable.................... 6 Assembling the plug-in connecting cable .......................... 6 Disassembling the plug-in connecting cable for tubular drives dia.
General These tubular drives are high-quality products with the following features: • Optimised for roller shutter operation • Installation without stops possible (from lower point to upper point) • Automatic detection of the lower limit position when using springs in conjunction with the "drive adapter for obstacle detec- tion"...
Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. Instructions for the user General information • All work, including maintenance and cleaning, on electrical installations as well as other system parts must always be performed by authorised specialists, in particular qualified electricians.
Page 5
• Moving parts of drives must be installed at a height of over 2.5 m above floor level or any other surface from which access to the drive is gained. • To ensure safe operation of the system after commissioning, the limit positions must be correctly set/ programmed in.
Intended use The type of tubular drive described in these instructions is intended solely for the operation of roller shutters. This type of tubular drive supports not only curtain attachment by means of springs but also mechanical anti-lifting devices (e.g., Zurfluh-Feller, Simu, GAH Alberts and Deprat).
Disassembling the plug-in connecting cable for tubular drives dia. 35. Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. On drives with a diameter Ø35, insert a suitable flathead screwdriver between the locating lug and the snap-in pin, so that the snap-in pin releases the locating lug from the plug.
Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58 Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. On drives with a diameter Ø45 or Ø58, insert a suitable flathead screwdriver right into the recess of the locating latch, so that the latch releases the locating lug from the plug.
Installation Assembling the drive Attention To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used. Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus weight of the shading solution).
Assembling the drive adapter with screw connection Put the drive adapter (1) onto the drive shaft of the tubular drive. For the assembly, use an M6 x 12 screw (3) with appropriate washer (2) and suitable screw retainer. Threaded hole (4) Securing the drive against axial displacement In order to secure the drive against axial displacement, we recommend screwing the drive adapter to the tube.
Page 11
For round tubes: First notch the tube on the motor side, so the lug of the thrust ring can also be pushed into the tube. There must be no play between the lug of the thrust ring and the tube. Assemble the tubular drive with the relevant thrust ring (1) and drive adapter (2).
Setting the limit positions with switches Setting the limit positions There are 3 ways to set the limit positions: • Upper stop to lower stop • Upper point to lower point • Upper point to lower stop The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times. If the tubular drive switches off prematurely while opening or closing, due to an obstruc- tion, the obstruction can be cleared by reversing a short way and removing the obstruc- tion.
Page 13
Upper point to lower point There is no shading solution length adjustment with this limit position setting. Set both switches to the delete setting. Execute a short drive command. Open to the desired upper limit position. Now reset the switch of the UP direction of rotation from the delete setting to the pro- gramming setting.
Deleting the limit positions using the switches Deleting individual limit positions It is possible to delete an individual limit position, if lower point to upper point without stops has been programmed with the switches. Reset the switch of the corresponding limit position from the programming setting to the delete setting.
Setting the limit positions using the programming unit Setting the limit positions There are 4 ways to set the limit positions: • Upper stop to lower stop • Upper point to lower point • Upper stop to lower point • Upper point to lower stop The limit position becomes fixed after the tubular drive has turned off automatically in the desired position three times.
Page 16
Lower point to upper point without stops There is no shading solution length adjustment with this limit position setting. Set both switches to the programming setting. Open to the desired upper limit position. Press the programming button of the programming unit for 3 seconds. ▻...
Page 17
Upper point to lower stop Set both switches to the programming setting. Open to the desired upper limit position. Press the programming button of the programming unit for 3 seconds. ▻ The tubular drive makes a "click" sound to confirm. Then move down to the lower limit position.
Deleting the limit positions using the programming unit Connect the wires of the tubular drive to those of the same colour in the programming unit and switch on the power supply. Please pause for 1 sec after the last drive command before beginning the deletion se- quence.
Deleting both limit positions Open/close the shading solution to a point between the limit positions. Press the programming button and keep it pressed. Then press down the travel button and keep it pressed. Now release the programming button, but continue to keep the travel button pressed. Next press the programming button again.
Page 20
Upper stop to lower stop Open to the permanent upper stop. ▻ The tubular drive switches off automatically. Then close to the permanent lower stop without pausing. During travel, the end posi- tion status indicator (ESI) must be displayed before the end position is reached. ▻...
Upper point to lower stop Open to the desired upper limit position. Carry out the sequence between the individual drive commands without pausing: ▻ The tubular drive makes a "click" sound to confirm. until STOP and hold until Then close to the permanent lower stop without pausing. During travel, the end posi- tion status indicator (ESI) must be displayed before the end position is reached.
Obstacle detection Caution Obstacle detection is only active in conjunction with the "drive adapter for obstacle detec- tion". In addition, please note that the drive must be pushed in to the shaft as far as the band of the thrust ring. Use of the drive’s obstacle detection system as personal protection is not permitted.
Information for the electrician Tubular drives with electronic limit switching can be connected in parallel. The maximum switching contact load of the switching equipment (timer, relay control, switch, etc.) must be observed. To operate drives with electronic limit switching, only use switch- ing elements (timers) that are not earthed via the drive.
Technical data dia. 35 Model P5-E01 P9-E01 Type P5/16C PRO+ P9/16C PRO+ Rated torque [Nm] Output speed [rpm] Limit switch range 64 revolutions Supply voltage 230 V AC / 50 Hz Connected load [W] Rated current consumption [A] 0.36 0.47 Mode S2 4 min Degree of protection...
What to do if...? Problem Cause Remedy The roller shutter curtain is raised un- 1. One or more attachments have Repair system; then re-program limit po- evenly or not at all. broken off. sitions. 2. Lath has broken off. Tubular drive overruns the limit position or A short circuit caused by dampness.
Sample wiring diagrams The assignment of the black and brown wires according to the direction of travel is de- pendant on how the drive is installed (mounted to the right or to the left). Controlling one/several drive(s) via a single switch/button...
Page 27
Central, group and individual control using Centronic UnitControl UC42 Central Control unit Mains 230 V / 50 Hz Central cable 230 V / 50 Hz (connection to further control units) Group 230 V / 50 Hz Individual Individual 230 V / 50 Hz 230 V / 50 Hz...