Becker S01 Assembly And Operating Instructions Manual

P5-16...r40-17 smi tubular drives for roller shutters

Advertisement

Quick Links

P5-16...R40-17
Model: S01
Assembly and Operating Instructions
en
SMI tubular drives for roller shutters
Important information for:
• Fitters / • Electricians / • Users
Please forward accordingly!
These instructions must be kept safe for future reference.
2010 300 918 0a     05/12/2018   
Becker-Antriebe GmbH
Friedrich-Ebert-Straße 2-4
35764 Sinn/Germany
www.becker-antriebe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Becker S01

  • Page 1 P5-16...R40-17 Model: S01 Assembly and Operating Instructions SMI tubular drives for roller shutters Important information for: • Fitters / • Electricians / • Users Please forward accordingly! These instructions must be kept safe for future reference. 2010 300 918 0a     05/12/2018   ...
  • Page 2: Table Of Contents

    Table of contents General .................................... 3 Warranty .....................................  3 Safety instructions ................................ 4 Instructions for the user.............................. 4 Instructions for installation and commissioning........................ 4 Intended use .................................. 6 Assembling and disassembling the plug-in connecting cable.................... 6 Assembling the plug-in connecting cable ..........................  6 Disassembling the plug-in connecting cable for tubular drives dia.
  • Page 3: General

    General These tubular drives are high-quality products with the following features: • Optimised for roller shutter operation • Installation without stops possible (from lower point to upper point) • Automatic detection of the lower limit position when using springs in conjunction with the "drive adapter for obstacle detec- tion"...
  • Page 4: Safety Instructions

    Safety instructions The following safety instructions and warnings are intended to avert hazards and to prevent property damage and personal injury. Instructions for the user General information • The drive must be disconnected from its power source during cleaning and maintenance and when re- placing parts.
  • Page 5 • Hazardous moving parts of the drive must be installed at a height of over 2.5 m above floor level or any other surface from which the drive can be accessed. • To ensure safe operation of the system after commissioning, the limit positions must be correctly set/ programmed in.
  • Page 6: Intended Use

    Intended use The type of tubular drive described in these instructions is intended solely for the operation of roller shutters. This type of tubular drive supports not only curtain attachment by means of springs but also rigid shaft connectors, such as mech- anical anti-lifting devices manufactured by Zurfluh-Feller, Simu, GAH Alberts and Deprat.
  • Page 7: Disassembling The Plug-In Connecting Cable For Tubular Drives Dia. 35

    Disassembling the plug-in connecting cable for tubular drives dia. 35. Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. Insert a suitable flathead screwdriver between the locating lug and the snap-in pin, so that the snap-in pin releases the locating lug from the plug.
  • Page 8: Disassembling The Plug-In Connecting Cable For Tubular Drives Dia. 45 And Dia. 58

    Disassembling the plug-in connecting cable for tubular drives dia. 45 and dia. 58 Caution Prior to disassembly, the power supply to the connecting cable must be disconnected. Insert a suitable flathead screwdriver right into the recess of the locating latch, so that the latch releases the locating lug from the plug.
  • Page 9: Installation

    Installation Assembling the drive Attention To connect the drive to the driven part, solely mechanical accessory components made by the drive manufacturer from the current product catalogue may be used. Prior to mounting, the fitter must ensure that the masonry and the system being motorised are sufficiently robust (drive torque plus weight of the shading solution).
  • Page 10: Disassembling The Drive Adapter With Safety Catch On The Drive Shaft

    Disassembling the drive adapter with safety catch on the drive shaft Disassembly with disassembly tool, Item no. 4930 300 606 0 Disassembly with long nose pliers Assembling and disassembling the drive adapter with separate drive adapter safety catch Assembling and disassembling the drive adapter with screw connection Mounting the drive in the tube For profile tubes: In the case of some drive adapters, tolerances of the groove widths in different bar-...
  • Page 11 For round shafts: Measure the lug of the thrust ring (X, Y). Then notch the tube on the motor side, so the lug of the thrust ring can also be pushed into the shaft. There must be no play between the lug of the thrust ring and the shaft. To ensure secure torque transmission for round shafts, we recommend screwing the drive adapter to the shaft (see the table below).
  • Page 12: Setting The Limit Positions Using The Programming Unit

    Setting the limit positions using the programming unit Up / retract button Programming button Down / extend button green/yellow green/yellow blue blue brown brown black black grey grey 1 = direction switch Connect the wires of the tubular drive to those of the same colour in the programming unit (Item No. 4935 200 034 0) and switch on the power supply.
  • Page 13 Intelligent installation management Limit position status indicator A brief stopping and restarting indicates that no limit position has been set in that direction of movement. Completion of installation following automatic setting of limit position "Stop" The drive saves the limit position "Stop" permanently once the it has been reached 3 times in succession. Installation is then com- plete.
  • Page 14 Upper point to lower point There is no shading solution length adjustment with this limit position setting. Open to the desired upper limit position. Press the programming button of the programming unit for 3 seconds. ▻ The tubular drive makes a “click” sound to confirm. Then close to the desired lower limit position.
  • Page 15: Deleting The Limit Positions Using The Programming Unit

    Deleting the limit positions using the programming unit Connect the wires of the tubular drive to those of the same colour in the programming unit and switch on the power supply. Please pause for 1 sec after the last drive command before beginning the deletion se- quence.
  • Page 16: Additional Upper Anti-Freeze Mechanism

    Deleting both limit positions Any additional functions that may have been set are deleted at the same time, or are reset to the factory default settings. Open/close the shading solution to a point between the limit positions. Press the programming button and keep it pressed. Then press down the travel button and keep it pressed.
  • Page 17: Obstacle Detection

    Obstacle detection Caution Obstacle detection is only active in conjunction with the "drive adapter for obstacle detec- tion". In addition, please note that the drive must be pushed in to the shaft as far as the band of the thrust ring. Use of the drive’s obstacle detection system as personal protection is not permitted.
  • Page 18: Information For The Electrician

    Information for the electrician Tubular drives with electronic limit switching can be connected in parallel. The maximum switching contact load of the switching equipment (timer, relay control, switch, etc.) must be observed. To operate drives with electronic limit switching, only use switch- ing elements (timers) that are not earthed via the drive.
  • Page 19: Technical Data Dia. 35

    Technical data dia. 35 Tubular drive P5-16 P9-16 Model Type C PRO+ SMI Rated torque [Nm] Output speed [rpm] Limit switch range 64 revolutions Supply voltage 230 V AC / 50 Hz Connected load [W] Rated current consumption [A] 0.36 0.47 Operating mode S2 4 min Degree of protection IP 44 Min.
  • Page 20: What To Do If

    What to do if...? Problem Remedy The roller shutter curtain is raised unevenly or not at all. Repair system; then re-program limit positions. Tubular drive overruns the limit position or does not reach the Repair electrical installation; re-program limit positions. set limit position.
  • Page 21: Sample Wiring Diagram

    Button operation is activated by turning the power supply on and off. The drive permanently changes to SMI mode as soon as SMI bus voltage is detected on the I+ and I- lines. Technical information as well as the KNX product database can be found on our homepage www.becker-antriebe.com...
  • Page 22: Assignment Table For The Smi Tubular Drives

    (Consider applying a serial number sticker) Manufacturer's code: 2 = Becker-Antriebe GmbH Project / customer Room Signature Signature Project manager / building contractor Installing company This assignment table is also available to you on our website: www.becker-antriebe.com for the electronic work.
  • Page 23: Declaration Of Conformity

    Declaration of conformity...

This manual is also suitable for:

E01Evo 20 rEvo 20 r bt