PS(+) drives

Type plate
Type designation: e.g. R 30/17 C PS+
R
Size of drive
(tube diameter)
P - 35 mm
R - 45 mm
L - 58 mm
30/17
Rated torque/output speed
C
Pluggable connecting cable
P
Point to point programmable
S
Electronic limit switching for sun
protection
+
Higher closing force for cassette
awnings
Operating mode (short-period operation
S2)
After 4 minutes of continuous operation,
the drive must be allowed to cool off.
Serial number: e.g. 09 01 961657
09
Year 2009
01
Calendar week
961657 Consecutive number
Wiring
Two or more drives with electronic limit switch-
ing can be connected in parallel to a control
point. The maximum number of synchronously
controlled drives depends on the load capacity
of the operator control.
The changeover time for switching the running
direction must be at least 0.5 seconds. The
switch and controls must not execute simulta-
neous retract and extend commands.
The following applies to operator controls with
a 5A contact load rating:
R5/20 PS - R12/17 C PS(+) =
max. 5 drives
R20/17 C PS(+) - R60/17 C PS(+) =
max. 3 drives
L70/17 C PS(+) - L120/11 C PS(+) =
max. 2 drives
Drive