With the combination of the input event, it looks like this:
!i1c!ess1001#
You can assign several commands to an input event. In this
case, attach the additional commands. The total number of
characters of a command line must not exceed 150 characters.
For example with the line
!i1c!ess1001!edv10:255#
If input 1 is closed, the
be activated and additionally the
255.
9.1.5

!d: DMX events

The whole
for a command. As operators
Example:
!d1=255!...# -> If the value of the
255, then the downstream command will be executed.
!d150<20!...# -> If the value of the
less than 20, then the downstream command will be executed.
!d512>175!...# -> If the value of the
is greater than 175, then the downstream command will be
74
executed.
open collector
DMX
univers can also be used as a start condition
> < =
outputs 1 and 4 will
DMX
channel 10 will be set to
are permitted.
DMX
channel 1 is equal
DMX
channel 150 is
DMX
channel 512