Structure Of The Control.ini File; I: Event Related To The Remote Inputs 1-16; T: Time Events - WEIGL ProCommander LX Instruction Manual

Hide thumbs Also See for ProCommander LX:
Table of Contents

Advertisement

Control.ini

10.1 Structure of the Control.ini file

It must always start with the definition of the input event:

!i: Event related to the remote inputs 1-16

Example:
!i1c# → if input 1 is activated (c=close).
!i1o# → if input 1 is deactivated (o=open).
!i1t# → if input 1 changes (t=toggle).

!t: Time events

The internal timer of the clock starts counting with zero
seconds, zero minutes and zero hours at the moment the device
is powered up. With insertion of the SD-card, this clock is also
set to „0" zero.
Each
minutes:seconds. Hours must be converted to minutes. A time
of 2 hours, 15 minutes and 20 seconds should be formatted as
135:20.
The character after the t determines the way the time should
be interpreted.
m is the absolute time after powering on the ProCommander
72
LX or after the insertion of a
new insertion of the card this time is set to zero.
time
value
must
be
entered
in
SD
card. After each removal or
the
format

Advertisement

Table of Contents
loading

Table of Contents