!rc(s&10)!...# -> all 10 seconds the downstream command
will be executed.
!rc(w>2;w<7;h=8)!...# -> from Tuesday till Saturday the
downstream command will be executed precisely at 8 a.m.
!rc(m&15)!...# -> at every quarter (0, 15, 30, 45) the
downstream command will be executed.
A real-time command will be executed, as soon as all
conditions within the round bracket are true. This condition has
to become "untrue" once, that the command will be executed
the next time it becomes "true" again.
For example the condition !rc(s&1)!...# would be executed
only once, because second modulo 1 is always "true".
9.1.4

!v: Variable events

For basic information about the variables read the chapter
"Variable".
After each change of a variable the Control.ini file is checked,
if an event is assigned to this variable.
If this variable condition is true, the following command will
be executed.
Immediately after the input event, the command definition
has to follow.
Example:
!ess1001# -> the
(see
ASCII
chart).
open collector
outputs 1 and 4 will be set
Control.ini