Mb1000 Test Program; How To Start The Inspection Program; Inspection Items; Switch Inspection - Yamaha DM1000 Service Manual

Digital production console/ peak meter bridge/wooden side panels
Hide thumbs Also See for DM1000:
Table of Contents

Advertisement

MB1000 TEST PROGRAM

This executes the MB1000 test program.
1.
Preparation
1) Connect the D-sub 15-pin cable to the [METER] terminal on the rear of the DM1000.
2) If there is no DM1000, supply +16.5 V power with an external power supply to the +12V terminal and the ground
terminal.
Note: If a stand-alone inspection is carried out with the unit installed on the DM1000 main unit, the Loopback test
generates an error.
2.

How to start the inspection program

1) While holding down the [PEAK HOLD] switch, the [33-48] switch, and the [MASTER] switch, switch on the power. The
unit goes into stand-alone inspection mode and the switch inspection starts.
2) When you press the [PEAK HOLD] switch, the [33-48] switch, and the [MASTER] switch again, LED Inspection 1
starts. (To inspect the switches again, it is necessary to switch the power off, then on again.)
3) From this point on, pressing the [REMOTE1] switch or the [REMOTE2] switch changes the inspection item.
4) During LED Inspections 6 and 7, pressing the [1-16] switch or the [17-32] switch changes the LED illumination time.
(Each time you press the [1-16] switch, the illumination speeds up; each time you press the [17-32] switch, the illumination
slows down.)
3.

Inspection Items

3-1. Switch Inspection

The operation of each switch is judged by whether the LED lights up or goes out when the switch is pressed.
Switch
1-16
17-32
33-48
PEAK HOLD
REMOTE1
REMOTE2
MASTER
3-2. LED Inspection
Inspection No.
1
REMOTE1↓↑REMOTE2
2
3
4
5
6
7
8
Inspection Item
Communications loopback test Normal: H10='0', Error: H10='E'
LED all light
Green LED all light
Orange LED all light
Red LED all light
Channel bar graph lit
(LED lighting order: CH1 Bottom → Top.. CH16 Bottom → Top, OUT BUS 1 Bottom → Top..
OUT BUS 2 Bottom → Top
Other lit
(INPUT METERING POSITION
OUTPUT METERING POSITION PRE EQ → PRE FADER → POST FADER →
1-16_L → 17-32_L → 33-48_L → AUX/BUS1-8_L →
1-16_M → 17-32_M → 33-48_M → AUX/BUS1-8_M →
1-16_R → 17-32_R → 33-48_R → AUX/BUS1-8_R →
1-16 SW → 17-32 SW → 33-48 SW →
PEAK HOLD SW → REMOTE1 SW → REMOTE2 SW → MASTER SW)
Time codes H10 → H1 → M10 → M1 → S10 → S1 → F10 → F1 light up repeatedly
(Lighting order: 0 → 1.. 9 →. (dot))
Action
1-16 light up/go out
17-32 light up/go out
33-48 LED light up/go out
PEAK HOLD LED light up/go out
REMOTE1 LED light up/go out
REMOTE2 LED light up/go out
MASTER LED light up/go out
PRE EQ → PRE FADER → POST FADER →
DM1000/MB1000/SP1000
143

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp1000Mb1000

Table of Contents