Connection Of The Control Board Version N; Assignment Of The Control Terminal Strip X2A - KEB COMBIVERT R6 Instruction Manual

Power supply and regenerative unit
Hide thumbs Also See for COMBIVERT R6:
Table of Contents

Advertisement

Connection of the control board version N

4.5
Connection of the control board version N
4.5.1

Assignment of the control terminal strip X2A

PIN Function
10
24V input
11
24V ground
12
Digital input 1
13
Digital input 2
14
Digital input 3
15
Digital input 4
16
Mass
17
24 V output
18
Mass
19
Digital output 1
20
Digital output 2
21
Analog output
22
24 V output
23
Mass
24
Relay 1 / NO contact
25
Relay 1 / NC contact
26
Relay 1 / switching
contact
27
Relay 2 / NO contact
28
Relay 2 / NC contact
29
Relay 2 / switching
contact
*) The relay outputs must be operated with max. 48 V DC protective separation voltage to
guarantee the CE standard. After consultation with KEB, a current of max. 2 A AC is per-
missible for 120 V AC (depending on the switching capacity etc.).
38
10 11 12 13 14 15 16 17 18 19 20 21 22 23
Core cross-section 0.14...1.5 mm², tightening torque 0.5 Nm
Name
Uin
COM
ST
I1
I2
I3
COM
Uout
COM
O1
O2
Error message Transistor output (error mes-
ANOUT
Uout
COM
RLA
RLB
RLC
FLA
FLB
FLC
X2A
Default
Description
External supply of the control
board
Reference potential: 24V input
Control release / reset
Set selection
programmable
Set selection
programmable
Ext. error
programmable
Reference potential
Voltage supply for in and
outputs
Reference potential
DC > 600V
Transistor output (DC >
CP.19)
sage)
Difference to mains frequen-
cy (CP.18)
see terminal 17
Reference potential
Ready for
operation (no
Relay output
error)
Ready signal ("Stb" or "rE-
GEn")
DC > 600V
Relay output
(DC > CP.19)
24 25 26 27 28 29
Specifications
21.6...26.4 V DC
/ 1 A
Ri: 4.4 kΩ
approx. 24 V /
max. 100 mA
I
: 25 mA
max
I
: 25 mA
max
0...±10 V / max.
5 mA
max. 30 V DC *)
0.01...2 A DC
max. 30 V DC *)
0.01...2 A DC

Advertisement

Table of Contents
loading

Table of Contents