Safety Instructions; General Instructions - KEB COMBIVERT R6 Instruction Manual

Power supply and regenerative unit
Hide thumbs Also See for COMBIVERT R6:
Table of Contents

Advertisement

2.

Safety Instructions

2.1

General instructions

Danger
Warning
Attention
Electric Shock
COMBIVERT R6 power supply and regenerative units contain dangerous
voltages which can cause death or serious injury.
COMBIVERT R6 can be adjusted by way that energy is regenerated into the
supply system in case of power failure at regenerative operation. Therefore
a dangerous high tension can exist in the unit after switching off the supply
system.
Before working with the unit check the isolation from supply by meas-
urements in the unit.
Care should be taken to ensure correct and safe operation to minimise risk
to personnel and equipment.
Only Qualified Electro-Personnel
All work from the transport, to installation and start-up as well as mainte-
nance may only be done by qualified personnel (IEC 364 and/or CENELEC
HD 384 and IEC-Report 664 and note national safety regulations). According
to this manual qualified staff means those who are able to recognise and
judge the possible dangers based on their technical training and experience
and those with knowledge of the relevant standards and who are familiar with
the field of power transmission.
Observe standards
The COMBIVERT must not be started until it is determined that the installa-
tion complies with the Machine directive (2006/42/EC) as well as the EMC-di-
rective (2004/108/EC)(note EN 60204).
The COMBIVERT meets the requirements of the Low-Voltage Directive
2006/95/EC. The harmonized standard of the series EN 61800-5-1 (VDE
0160) is used.
This is a product of limited availability in accordance with IEC 61800-3. This
product may cause radio interference in residential areas. In this case, the
operator must take appropriate measures.