Special Unit Peak Power - KEB COMBIVERT R6 Instruction Manual

Power supply and regenerative unit
Hide thumbs Also See for COMBIVERT R6:
Table of Contents

Advertisement

Technical Data
3.2

Special unit Peak Power

Inverter size
Housing size
Phases
Approaved mains phases
Rated voltage
Input voltage UL
Mains voltage range
Mains frequency
DC voltage range
Regenerative operation
Output rated power
Rated active power
Max. power output
Max. active power
Regenerative rated current
Regenerative DC current
Overload current (E.OL) 10 s
Max. regenerative DC current 10 s
Power supply operation
Input rated power
Rated active power
Max. input power 10 s
Max. active power 10 s
Rated supply current
DC supply current
Overload current (E.OL) 10 s
Max. DC supply current 10 s
Overload disconnection (E.OL)
Overvoltage switch-off (E.OP)
Rated output voltage
Max. permissible DC link capacity
I
t Integral of the limiting load of the semiconductor
2
Max. permissible mains fuse type gR / aR
Permissible aR fuse Siemens Sitor / Bussmann (no delta power
system)
Line fuse for UL type RK1 "fast acting" or "J fast acting"
Short-circuit factor at the connection point (S
Power dissipation at nominal operating
Max. heat sink temperature
Bracket values obtain for operation at 230 V power supply. The unit is automatically adjusted by the soft-
*)
ware when switching on.
The current data are based on a fundamental frequency component of g=0.95. The fundamental fre-
1)
quency component or the effective value of the input current is dependent on load and line supply
conditions. At uncontrolled B6 converters the phase angle cosφ1 can be set to one, so the value of the
fundamental frequency components is equal to the value of the power factor.
If the DC supply current > 85 A DC use two by two of the DC terminals (++ and --) to meet the require-
2)
ments of the UL standard.
The connection cables are parallel connected.
After consultation KEB IT and delta power system (see also safety instructions, voltage with respect to
3)
ground)
18
*)
[V]
*)
[V]
[V]
[Hz]
*)
[V
]
DC
Sn *)
[kVA]
*)
[ kW ]
*)
[kVA]
*)
[ kW ]
[A]
[A
]
DC
[A]
[A
]
DC
Sn *)
[kVA]
*)
[ kW ]
*)
[kVA]
*)
[ kW ]
1)
[A]
2)
[A
]
DC
[A]
[A
]
DC
[%]
[V
]
DC
[V
]
DC
*)
[µF]
[A
s]
2
[A]
" / S
) or (S
/ S
)
kn
n
scp
n
[W]
[°C]
Special unit Peak Power 19 (16)
E
3
TN, TT
3)
400 (230)
240/400/480
180...550 ±0 %
50 / 60 ±2
250...780 (UL: 340...680)
45
(26)
42
(23)
81
(46,6)
75
(42)
65
80
117
144
48.5
(28)
44.5
(25.5)
87
(50)
80
(46)
70
87
126
156
200
900
540 (310)
10000
(42000)
3058
100
3NC2240 / FWP-40A22FA
90A / 480V (90A / 250V)
20 < S
" / S
< 350
kn
n
430
88