PERCo ST-01 Assembly And Operation Manual

Speed gate/double-sided section
Hide thumbs Also See for ST-01:

Advertisement

Quick Links

Speed Gate
ST-01
Double Sided Section
STD-01
ASSEMBLY AND OPERATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for PERCo ST-01

  • Page 1 Speed Gate ST-01 Double Sided Section STD-01 ASSEMBLY AND OPERATION MANUAL...
  • Page 2 ST-01 Speed gate STD-01 Double-sided section Assembly and Operation Manual...
  • Page 3: Table Of Contents

    2  OPERATING CONDITIONS ....................3  3  TECHNICAL SPECIFICATIONS ..................... 4  4  DELIVERY SET ........................4  4.1  Standard delivery set......................4  4.1.1 ST-01 Speed gate........................4     4.1.2 STD-01 double-sided section ....................5     4.2  Optional equipment ......................6 ...
  • Page 4: Application

    Due to continuous improvement of products, the Manufacturer reserves the right to modify, without previous notice, the product design not aggravating its technical specifications. 1 APPLICATION ST-01 Speed gate (hereinafter – the speed gate) is designed for pedestrian passage control at entrance points of administrative buildings, banks, shops, railway terminals, airports, etc. Attention! ST-01 speed gate is designed for the passage of pedestrians taller than 1 m, otherwise correct operation of the speed gate is not guaranteed.
  • Page 5: Technical Specifications

    The power supply is connected to the control board located in the Master section (on the Master side of the double-sided section) and has the “ST-01.771” marking. Current consumption and power consumption are given for each product ST-01 and STD-01 individually. Maximum allowable cable length of the RC panel is 40 m (supplied upon request).
  • Page 6: Std-01 Double-Sided Section

    Certificate ........................1 (in box #1) Assembly and operation manual ................1 (in box #1) Packaging: Box #1 for ST-01/M section ......................1 Box #2 for ST-01/S section ......................1 Box for section top covers ......................1 Box for swing panels ........................1 4.1.2 STD-01 double-sided section...
  • Page 7: Optional Equipment

    Note: The type of top cover is to be chosen by the Customer. The following top cover models for the ST-01 speed gate are available:  STC-01G – is made of tempered glass and features built-in indication block;  STC-01S – is made of stainless steel, features a plastic plate, indication block is not provided;...
  • Page 8 ST-01 Speed gate, STD-01 Double-sided section Figure 1. Speed gate overall dimensions with ATG-300 swing panels Figure 2. Speed gate overall dimensions with ATG-300H swing panels...
  • Page 9 Assembly and Operation Manual Figure 3. Speed gate overall dimensions with ATG-425 swing panels Figure 4. Speed gate overall dimensions with ATG-475 swing panels...
  • Page 10: Design And Operation

    ST-01 Speed gate, STD-01 Double-sided section Figure 5. Speed gate overall dimensions with several passage lanes 5 DESIGN AND OPERATION 5.1 Main features  The speed gate allows to perform several authorized single passages in a row in one direction without the swing panels being closed.
  • Page 11 Assembly and Operation Manual Figure 6. ST-01 overall view: 1 – swing panel; 2 – central post; 3 – central post indication block; 4 – swing panel cover plate; 5 – central post cover plate; 6 – central post rear panel;...
  • Page 12 20 – to the Master section (side) CAN cable; 21 – from the Slave section (side) DC cable ; 22 – from the Slave section (side) CAN cable Not included in the standard delivery set. From ST-01 or other STD-01 delivery set.
  • Page 13: Design

    Assembly and Operation Manual  The equipment can operate as an operating device as a part of ACS or as a standalone unit operated from the RC-panel.  The speed gate provides the possibility of proximity card readers installation inside the posts under the glass section top cover.
  • Page 14: Indication Blocks

    (blocks) (11), that consists of passage granting indicator (green arrow) and access card presentation zone indicator (“hand with a card” pictogram). The bottom part of the Master section central post features ST-01.771 speed gate control board (hereinafter – control board). The PS, the RC-panel (WRC receiver), Fire Alarm device and Slave section connection cables are connected to the control board.
  • Page 15: Control Board

    Assembly and Operation Manual Figure 8. Overall view and dimensions of the RC-panel 1, 2, 3 – LEFT, STOP, RIGHT buttons for mode setting; 4, 6 – green “Left”, “Right” indicators; 5 – red “Stop” indicator 5.2.4 Control board Speed gate control board (Fig. 9) is installed in the central post of Master section. Remove the central post cover plate in order to access the board (see Sect.
  • Page 16 ST-01 Speed gate, STD-01 Double-sided section Connector blocks to connect:  X1 (Power) – speed gate power supply.  X2 (RC) – operating devices: RC-panel, wireless remote control, control outputs of the ACS-controller, Fire Alarm device.  X3 (ACS) – sirens and ACS-controller inputs to the control board outputs.
  • Page 17: Control Signals

    Assembly and Operation Manual Table 3. Function of the control board terminal block contacts Connector block № Contact Function +24V External power supply connection X1 (Power) General A direction control input Unlock A Passage denial control Input Stop B direction control input Unlock B A direction control input on the RC-panel Led A...
  • Page 18: Control Modes

    ST-01 Speed gate, STD-01 Double-sided section Figure 10. Control elements of the external device – normally open relay contact Figure 11. Control elements of the external device – open collector output layout 5.2.6 Control modes There are two speed gate control modes – pulse and potential. In both modes the speed gate is controlled by sending commands (i.e.
  • Page 19: Speed Gate Operation Algorithm

    Assembly and Operation Manual Potential control mode The mode is used for speed gate operation with ACS-controller. The outputs of the ACS-controller are to support potential control mode. Speed gate operation in potential control mode is described in Table 8. Control signal duration at sending control command to control inputs is to be not less than 100 ms.
  • Page 20: Operating Devices

    ST-01 Speed gate, STD-01 Double-sided section 9. After the passage is completed and the swing panels are closed, the speed gate is ready for another passage. In potential speed gate control mode, the control signal can be released after receiving a signal from PASS output for the same direction.
  • Page 21: Fire Alarm Device

    Assembly and Operation Manual 5.3.2 Fire Alarm device Connect the Fire Alarm emergency passage unlocking device to control board Fire Alarm input (Fire Alarm and GND contacts of the X2 terminal block) according to the speed gate connection layout (Fig. 18). If the Fire Alarm input is not used, a jumper between Fire Alarm and GND contacts of the control board is to be installed.
  • Page 22: Siren

    ST-01 Speed gate, STD-01 Double-sided section Pass elements – relay contacts (Fig. 13) with the following signal characteristics: maximum commutation DC voltage ................42 V maximum commutation current ..................0.25 A closed contact resistance ................max 0.15 Ohm 5.4.2 Siren...
  • Page 23: Marking And Packaging

    Box with ATG-425 (set of swing panels) .............78×60×12 cm Box with ATG-425 (set of swing panels) ...............78×65×8 cm Transportation boxes weight (gross): ST-01: Box #1 (ST-01/M section) ................. max 125 kg Box #2 (ST-01/S section) .................. max 125 kg STD-01: Box #1 (double-sided section) ................max 140 kg Box with STC-01 (set of section top covers) ............
  • Page 24: Operation Safety Requirements

    ST-01 Speed gate, STD-01 Double-sided section Power supply installation should be performed with observance of safety rules, given in its operation manual. Operation safety requirements Observe general electrical safety rules when operating the speed gate. Attention!  Do not use the speed gate in conditions that do not comply with the requirements given in Sect.
  • Page 25: Cable Length

    Sect. 8.2. Figure numbers are given in accordance with Fig. 6 and 7. Speed gate connection layout is given in Fig. 18. Types of cables used are stated in Sect. 8.3. The example of ST-01 and STD-01 connection layout with extra passage lane arrangement is shown in Fig. 17.
  • Page 26 There are numbers on the cut-off ends of the core that correspond to the connection layout (Fig. 18). Unpack the Master section (box №1, ST-01/M). Do not work alone! Carefully take the section out of the box by holding it by the top duct.
  • Page 27 (installer) in accordance with the checkpoint design and the characteristics of the access control system and the control controller. It is possible to install readers as manufactured by PERCo (IR03.1, MR07 OEM, RP-15.2), and third-party manufacturers. Readers must meet the following requirements: Overall dimensions (length ×...
  • Page 28: Mounting Surface Marking Layouts

    ST-01 Speed gate, STD-01 Double-sided section 8.5 Mounting surface marking layouts Figure 15. Speed gate marking layout (ATG-425 swing panel dimensions are given in brackets)
  • Page 29 Assembly and Operation Manual Figure 16. Speed gate and double-sided section marking layout (ATG-425 swing panel dimensions are given in brackets)
  • Page 30: Speed Gate Wiring Diagram

    ST-01 Speed gate, STD-01 Double-sided section 8.6 Speed gate wiring diagram Figure 17. ST-01 speed gate and STD-01 double-sided section wiring diagram Table 6. List of the elements of speed gate wiring diagram Legend Name Nr, pc. Master section (section side) A1.1...
  • Page 31: Training Mode

    Assembly and Operation Manual Figure 18. Speed gate wiring diagram 8.7 Training mode The mode allows adjusting manually speed gate swing gates initial position. Proceed as follows: Turn off the speed gate power supply. Switch the R2 switch to the ON position (R1 switch should be in OFF position). Arrange the swing panels into the required initial position and adjust them relatively to each other.
  • Page 32: Auto-Opening In The Selected Direction" Mode

    ST-01 Speed gate, STD-01 Double-sided section Turn on the speed gate power supply. The swing panel will make a search for the end positions and get back into the initial position. The swing panel position data will be registered in the control board memory.
  • Page 33: Assembly And Disassembly Of The Speed Gate Components

    Assembly and Operation Manual 8.9 Assembly and disassembly of the speed gate components Attention! Speed gate components are made of polished stainless steel and glass. Be careful during the assembly, to prevent the components from falling and damage, place them on an even and steady surface, prevent them from scratches.
  • Page 34: Front Panel Of The Side Post

    ST-01 Speed gate, STD-01 Double-sided section 8.9.2 Front panel of the side post Remove the side post front panel (8), moving it up along the post and then pull it, bringing the hooks from slots in the side post (Fig. 20). Be careful not to damage the connection cable! Disconnect the connection cable output from the front-end indication block.
  • Page 35: Swing Panel Cover Plate

    Assembly and Operation Manual 8.9.4 Swing panel cover plate Swing panel cover plate (4) consists of two parts. In order to install the cover plate, proceed as follows: 1. Turn fully the rotating support of swing panel in the clockwise direction. 2.
  • Page 36: Central Post Indication Block

    ST-01 Speed gate, STD-01 Double-sided section 8.9.5 Central post indication block In order to install the central post indication block (3), proceed as follows (Fig. 22): 1. Pull the cable from central post indication block into the post top duct through the hole above the central post.
  • Page 37: Section Top Cover

    Assembly and Operation Manual 8.9.6 Section top cover Prior to installation of the section top cover (10), check whether all cables have been properly connected to the indication control module (see Fig. 20, Sect. 8.9.2). Installation order of the STC-01G (SDC-01G) and STC-01S (SDC-01S) section top covers (see Fig.
  • Page 38 ST-01 Speed gate, STD-01 Double-sided section  Install the additional equipment on the metal insert of the top cover.  Route the additional equipment connection cables through the central post to their connection point.  Mount the central insert with additional equipment on its place, fix it with two M5×16 screws using a SW4 Allen wrench.
  • Page 39: Bottom Duct Cover

    5. Remove both covers from the bottom duct (14) (Sect. 8.9.7). 6. For ST-01 section: remove the central post rear panel (6). Unscrew 2 M6×16 screws (for SW5 Allen wrench) in the bottom ducts, M6×16 screws (for SW5 Allen wrench) at the bottom of the central post and 2 M5×12 screws (for SW4 Allen wrench) in the top duct (Fig.
  • Page 40 ST-01 Speed gate, STD-01 Double-sided section Figure 27. Filling glass fixing in the ST-01 central post Figure 28. Filling glass fixing in the central post of the double-sided section STD-01 Figure 29. Central post rear panel disassembly...
  • Page 41: Operation

    Assembly and Operation Manual 9 OPERATION Follow the instructions of speed gate operation in accordance with Sect. 7.2. Attention!  Do not move through the speed gate passage area any objects with dimensions exceeding the width of the passage lane. ...
  • Page 42: Potential Control Mode

    ST-01 Speed gate, STD-01 Double-sided section  After sending “Single passage in a set direction” command speed gate intrusion detectors control the presence of a user in the passageway. After completing the passage, the speed gate switches to the “Always locked” mode.
  • Page 43: Fire Alarm" Mode

    Also, as a power loss, the swing panels can be opened manually (they are not blocked). 9.4.3 Troubleshooting Possible faults to be corrected by the customers themselves are listed in Table 9. For faults not listed in Table 9 we advise to consult with PERCo Technical Support Department. Table 9. Troubleshooting and remedy Most probable...
  • Page 44: Appendix 1. Operation Algorithm At Pulse Control Mode

    ST-01 Speed gate, STD-01 Double-sided section Appendix 1. Operation algorithm at pulse control mode “Always locked” (locked for entry and exit) – active front at the Stop contact while there is a high level at the Unlock A and Unlock B contacts. Both passage directions are locked at this command.
  • Page 45 PERCo Polytechnicheskaya str., 4, block 2 194021, Saint Petersburg Russia Tel: +7 812 247 04 64 E-mail: export@perco.com support@perco.com www.perco.com...
  • Page 46 www.perco.com...

This manual is also suitable for:

Std-01