Turn on the speed gate power supply. The swing panel will make a search for the end
positions and get back into the initial position. The swing panel position data will be registered
in the control board memory.
Note:
If in the training mode the speed gate switches into the "Emergency" mode, that indicates
the incorrect initial position of the swing panels. Turn off the speed gate power supply in
order to exit the "Emergency" mode. In order to continue with the training mode, install the
swing panels into the initial (locked) position and turn on the speed gate power supply.
5
Turn off the speed gate power supply.
6
Switch the R2 switch to the OFF on the control board.
7
Turn on the speed gate power supply. The swing panels will make a search for the end
positions and get back into the initial (locked) position. The speed gate is ready for operation.

8.8 "Auto-opening in the selected direction" mode

This additional operating mode is used, when it is required to organize free entrance (or exit)
keeping the swing panels in closed position and to prevent an unauthorized access in the opposite
direction (e.g. in the sales area of the store etc.).
Selection of the operating modes can be performed by switching R1 and R2 switches on the
control board (see Fig. 9 and Table 2).
Attention!
Change the position of the switches only when the speed gate is turned off.
This operating mode allows to organize the free passage in one preselected direction, when the
swing panels automatically open and close after the passage. In the direction selected for the
"Auto-opening" mode, if the speed gate is not occupied for passage from the opposite direction,
the green indicator (passage granting) is constantly lit, but in the other direction of the passage the
red indicator (passage denial) is lit. In case if the passage from the opposite direction is authorized
(from RC-panel, WRC-kit or ACS-controller), the "Auto-opening" mode is turned off for the time of
this passage.
Mode operation algorithm:
1) By default, the green indication is on in the "Auto-opening in the selected direction" mode in
free passage direction and the red indication is on in the other direction. RC commands or
ACS-controller commands for the passage in the "Auto-opening in the selected direction"
mode are ignored.
2) The intrusion detectors send a command to the speed gate controller to open the swing panels
when the visitor walks through the passage lane in the "Auto-opening in the selected direction"
mode direction. The swing panels open in this direction, and when the passage in completed,
the intrusion detectors send a command to the controller and the swing panels automatically
close. The indication stays in its initial state.
3) When the passage is performed in the direction opposite to "Auto-opening in the selected
direction" mode direction – the operation algorithm is equal to the ordinary algorithm (Sect.
5.2.7). During the authorized passage, the "Auto-opening in the selected direction" mode
switches off for the passage waiting period. If the "Free passage" mode is applied for this
direction, then the passage waiting period will be deactivated while this mode is applied.
4) All other cases such as simultaneous passage in both directions are considered as abnormal
and then the controller will generate an emergency signal and will close the swing panels.