9.4.2 "Fire Alarm" mode

In case of hazardous situations on the territory of the facility, the speed gate zone can be used as
an additional emergency exit.
It is possible to place the speed gate into the "Fire Alarm" mode from the emergency opening
device (Fire alarm device, emergency button, etc.). In this mode, the swing panels open in one of
the directions and remain open for free passage in both directions; simultaneously, for both
directions, green indicators of the pass enable in the flashing mode are switched on in the
indication block. Other commands at this mode are ignored (Sect. 5.3.2).
Also, as a power loss, the swing panels can be opened manually (they are not blocked).

9.4.3 Troubleshooting

Possible faults to be corrected by the customers themselves are listed in Table 9.
For faults not listed in Table 9 we advise to consult with PERCo Technical Support Department.
Fault
Power supplies are on, but
the speed gate does not
function, the RC-panel lights
and the LED indicators are
off.
One of the indication blocks
does not work, while the
speed gate operation
corresponds to the algorithm

10 MAINTENANCE

Technical maintenance is to be performed by qualified specialists after careful study of this
Manual.
Use liquid nonabrasive cleaners, containing aqua ammonia to remove the contaminations of the
speed gate sections and swing panels.

11 TRANSPORTATION AND STORAGE

Speed gate storage is allowed in dry indoor facilities at an ambient air temperature from -40°C to
+50°C at relative air humidity 80% at +15°C.
Speed gate in the original package should be transported in closed freight containers or others
closed type cargo transport units.
Do not stack the boxes with the speed gates during transportation and storage.
After transportation or storage at temperatures below zero or at high air humidity, prior to
installation the speed gate must be kept in the original package for no less than 24 hours indoors
at room temperatures.
42
Table 9. Troubleshooting and remedy
Most probable
cause
Faulty connection or
breakdown in the
speed gate power
supply cable.
No control signal is
sent to the indication
block
Remedy
Disconnect the speed gate power supply from
the mains, open the central post cover plate.
Check the integrity of the power cable, check
the reliability of the power cords in the XT3
terminal block of the control board.
Check the integrity of the connecting cable of
the indication block, check the reliability of its
connection in the connectors.