Table 3. Function of the control board terminal block contacts
Connector block
X1 (Power)
X2 (RC)
X3 (ACS)
X4

5.2.5 Control signals

Speed gate operation is performed by sending control signals to Unlock A, Stop and Unlock B
outputs. The control signal is sending a low-level signal to Unlock A, Stop and Unlock B contacts
regarding GND contacts. Normally open relay contact or layout with an open collector output can
serve as a control element (Fig. 10 and 11).
Speed gate emergency unlocking is performed by sending a control signal to Fire Alarm input. The
control signal is a low-level signal release from Fire Alarm contact regarding GND contact. A
normally closed relay contact or an open collector output layout can serve as a control element. In
this case all other incoming control commands are ignored. Sending a low-level signal to
Fire Alarm input, "Always locked" mode is activated, in which the swing panels get closed
(Sect. 5.3.2).
Note:
Use 1 kOhm resistors connected to + 3,3 V voltage plane to generate a high-level signal on
all input contacts (Unlock A, Stop, Unlock B, Fire Alarm).
Control element is to provide the following characteristics of the signals:
control element – relay contact:
minimum commutated current ............................................................................. max 4 mA
closed contact resistance
(regarding connection cable resistance) ....................................................... max 200 Ohm
control element – open collector output layout:
closed contact voltage (low level signal, on the control board input) .................. max 0.8 V
16
Contact
1
+24V
External power supply connection
2
GND
1
General
GND
2
A direction control input
Unlock A
3
Passage denial control Input
Stop
4
B direction control input
Unlock B
5
A direction control input on the RC-panel
Led A
6
Passage denial control input on the RC-panel
Led Stop
7
B direction control input on the RC-panel
Led B
8
RC-panel sound signal output
Sound
9
Fire Alarm
Emergency passage unlocking control input
10
GND
1
+12V output for additional equipment powering
+12V
2
General
GND
3
Alarm1
Siren connection output
4
Alarm2
5
Common for PASS A, PASS B outputs
Common
6
PASS A relay contact (passage in A direction)
PASS A
7
PASS B relay contact (passage in B direction)
PASS B
1
Normally open contact of the Light A output
NO1
2
Common contact of the Light A output
C1
3
Normally closed contact of the Light A output
NC
4
Normally open contact of the Light B output
NO2
5
Common contact of the Light B output
C2