Hardware Information
PG 7xx - PG 6xx
Connection to
PLC-S5 Port
7
PG 7xx - PG 7xx
Connection in
V.24 Operation
7-18
If you want to connect your PG 760 to the PLC-S5 port of a PG 6xx
programming device, you will need an adapter. In this case, the PG 760 must
be switched to active. Please read the notes on changing over the TTY/COM
1 port to active in Chapter 4.
PG 7xx
25-pin cannon plug connector
Port: COM1/TTY
active
+U
–U
+U
–U
Casing
Figure 7-13
PG 7xx - PG 6xx Connection to PLC-S5 Port
With this connecting cable you can connect to any PG 7xx.
Pay attention to the connecting polarities!
25-pin
Casing
Casing
TxD
2
2
RxD
3
3
RTS
4
4
CTS
5
5
DSR
6
6
GHD
7
7
DTR
20
20
Figure 7-14
PG 7xx - PG 7xx Connection in V.24 Operation
Note
The Product Information Bulletin enclosed with your computer contains further

technical information.

Adapter
Connecting cable
PG 6xx
6ES5 731-6AG00
6ES5 733-2xxx0
25-pin cannon plug connector
(Rel. 2)
with S5/V.24 passive port
330 ohms
22
6
19
10
8
18
21
330 ohms
8
19
10
21
9
12
10
24
Casing
24
25
Shield/casing
25
12
1
23
20
2
GND
3
6
2
K3
20
3
3
4
K2
4
17
17
K1
Connecting cable: 6ES5733-0BD20
Shield
1
Casing
3
2
5
4
20
7
17
6
PG 760 Programming Device
25-pin
1
Shield
Casing
3
RxD
2
TxD
5
CTS
4
RTS
20
DTR
7
GHD
17
AKENI
6
DSR
C79000-G7076-C761-01