Connecting The Pg 760 To The Power Supply - Siemens SIMATIC PG 760 Manual

Hide thumbs Also See for SIMATIC PG 760:
Table of Contents

Advertisement

Installing and Operating the PG 760
3.1
Connecting to the
Power Supply
3
Selecting Mains
Voltage
3-2

Connecting the PG 760 to the Power Supply

The PG 760 can be operated at 120 V or 230 V. Voltage selection is carried
out via the mains voltage selector.
Caution
!
Risk of damage to the unit!
Operating the PG 760 with the incorrect mains voltage can damage the unit.
When switched on, the same voltage is present on the appliance socket
(outlet) as on the appliance plug (mains inlet). To operate the monitor, please
observe the manufacturer's specifications. Only a monitor with the following
rated currents may be connected to the appliance socket:
115 V
230 V
If the set voltage does not correspond to your local voltage, you must select
the correct voltage by moving the mains voltage selector either to 115 V or
230 V. Proceed as follows:
Proceed as follows to switch over the voltage:
1. For 120 V, using a normal screwdriver push the mains voltage selector
right. 115 V appears above the switch.
2. For 230 V, using a normal screwdriver push the mains voltage selector
left. 230 V appears below the switch.
Figure 3-1 Mains Voltage Selector
1 A max.
0.5 A max.
Appliance socket
(outlet)
Appliance plug
(inlet)
230 Volt
Mains voltage Selector
115 Volt
Mains voltage
selector
PG 760 Programming Device
C79000-G7076-C761-01