The electrical installation shall be ac-
cording to national wiring rules.
Connect the appliance to a power sock-
et with a residual current circuit breaker
of rated residual current no more than
30 mA; minimum fuse 6 amperes.
Before each use, check the equipment,
cable and plug for damage. Defective
cables are not to be repaired, but rather
replaced by new ones. Have damage
on your equipment repaired by an au-
thorised specialist.
If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer, a customer service agent
of the same or a similarly qualified
person in order to prevent hazards. The
line must be minimum 10 m long.
Do not pull the plug from the socket by
the cable. Protect the cable from heat,
oil and sharp edges.
Do not carry or fix the equipment by the
cable.
Use only extension cables that are pro-
tected from spray water and designed
for outdoor use. Always fully unroll a
cable drum before use. Check the cable
for damage. The flexible lead cross-
section of the extension cord must at
least 2.5 mm
.
2
Disconnect the mains plug from the
socket before all work on the equip-
ment, in case of leaks in the water sys-
tem, during work breaks, and when not
in use.

Initial Operation

Positioning/Hanging

The dimensions of the pump shaft must
be not less than 40 x 40 x 50 cm, in
order that the float switch (
move freely.
8
The pump can be suspended by the
round handle (
shaft floor.
The pump can be suspended and/or
removed using the nylon cord (
provided.
To hang up safely, loop the nylon cord
around both of the cable holders that
are pointing downwards and pull it up-
wards through the round handle.
Never suspend the pump by the hose.

Mains Connection

The pump you have purchases is already
fitted with an earthed plug. The equipment
is designed for connection to an earthed
wall socket with a residual current operated
device (RCD switch) at 230 V ~ 50Hz.

Connecting the Pressure Line

The pump is installed
-
Either with a fixed pipeline
-
Or with a flexible hose line.
7) can
1) or placed on the
Ensure that the equipment is
not hung up or held by the
mains cable. There is a risk of
electric shock from damaged
mains cables.
Note that, over time, dirt and sand
may collect on the bottom of the
shaft, which could damage the
pump.
We recommend standing the pump
on a brick.
If the water level is too low, the silt in
the shaft can quickly dry out and im-
pede the pump when warming up.
1. Screw the bracket adapter (10)
onto the pump outlet (3).