Initial Operation; Positioning/Hanging - FLORABEST FTS 1100 B2 Translation Of Original Operation Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
GB
IE
earthing; the residual current circuit
breaking must be compliant with
the safety regulations of the energy
supply company and function with-
out fault,
-
The protection of the electrical plug
connections from the wet.
-
If there is a risk of flooding, fix the
plug connections in an area that is
safe from flooding.
Ensure that the mains voltage matches
the specifications on the rating plate.
The electrical installation shall be ac-
cording to national wiring rules.
Connect the appliance to a power
socket with a residual current circuit
breaker of rated residual current no
more than 30 mA; minimum fuse 6 am-
peres.
Before each use, check the equipment,
cable and plug for damage. Defec-
tive cables are not to be repaired, but
rather replaced by new ones. Have
damage on your equipment repaired
by an authorised specialist.
If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer, a customer service agent
of the same or a similarly qualified per-
son in order to prevent hazards. The
line must be minimum 10 m long.
Do not pull the plug from the socket by
the cable. Protect the cable from heat,
oil and sharp edges.
Do not carry or fix the equipment by
the cable.
Use only extension cables that are pro-
tected from spray water and designed
for outdoor use. Always fully unroll
a cable drum before use. Check the
cable for damage. The flexible lead
cross-section of the extension cord must
at least 2.5 mm
8
.
2
Disconnect the mains plug from the
socket before all work on the equip-
ment, in case of leaks in the water
system, during work breaks, and when
not in use.

Initial Operation

Positioning/Hanging

The dimensions of the pump shaft must
be not less than 40 x 40 x 50 cm, in
order that the float switch (
move freely.
The pump can be suspended by the
round handle (
shaft floor.
The pump can be suspended and/or
removed using the nylon cord (
provided.
To hang up safely, loop the nylon cord
around both of the cable holders that
are pointing downwards and pull it up-
wards through the round handle.
Never suspend the pump by the hose.
Ensure that the equipment is
not hung up or held by the
mains cable. There is a risk
of electric shock from dam-
aged mains cables.
Note that, over time, dirt and sand
may collect on the bottom of the
shaft, which could damage the
pump.
We recommend standing the pump
on a brick.
If the water level is too low, the silt
in the shaft can quickly dry out and
impede the pump when warming
up.
7) can
1) or placed on the
11)