Initial Operation; Positioning/Hanging - FLORABEST FTS 1100 C3 Translation Of Original Operation Manual

Dirty water submersible pump
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
GB
The equipment is not to be operated if
there are people in the water. There is
a risk of electric shock.
After erection, the mains plug must be
freely accessible when the equipment
is in operation.
Before operating your new pump,
have a specialist check:
-
The earthing, the protective multiple
earthing; the residual current circuit
breaking must be compliant with
the safety regulations of the energy
supply company and function with-
out fault,
-
The protection of the electrical plug
connections from the wet.
-
If there is a risk of flooding, fix the
plug connections in an area that is
safe from flooding.
Ensure that the mains voltage matches
the specifications on the rating plate.
The electrical installation shall be ac-
cording to national wiring rules.
Connect the appliance to a power
socket with a residual current circuit
breaker of rated residual current no
more than 30 mA; minimum fuse 6 am-
peres.
Before each use, check the equipment,
cable and plug for damage. Defec-
tive cables are not to be repaired, but
rather replaced by new ones. Have
damage on your equipment repaired
by an authorised specialist.
If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer, a customer service agent
of the same or a similarly qualified
person in order to prevent hazards.
Do not pull the plug from the socket by
the cable. Protect the cable from heat,
oil and sharp edges.
Do not carry or fix the equipment by
8
the cable.
Use only extension cables that are pro-
tected from spray water and designed
for outdoor use. Always fully unroll a
cable drum before use. Check the ca-
ble for damage.
Disconnect the mains plug from the
socket before all work on the equip-
ment, in case of leaks in the water
system, during work breaks, and when
not in use.
The cross-section of mains connection
lines must be no smaller than rub-
ber hose lines with the designation
H07RN8-F. The line must be 10 m long.
The flexible lead cross-section of the
extension cord must at least 2.5 mm

Initial Operation

Positioning/Hanging

The dimensions of the pump shaft must
be not less than 40 x 40 x 50 cm, in
order that the float switch (
move freely.
The pump can be suspended by the
round handle (
shaft floor.
The pump can be suspended and/or
removed using the nylon cord (
provided.
To hang up safely, loop the nylon cord
around both of the cable holders that
are pointing downwards and pull it up-
wards through the round handle.
Never suspend the pump by the hose.
Ensure that the equipment is
not hung up or held by the
mains cable. There is a risk
of electric shock from dam-
aged mains cables.