Figure 3-38 Cfm For An Unprotected Channel (100/0 Or 0/100); Figure 3-39 Cfm For A Protected Channel (90/10, 10/90, Or 50/50) - Cisco ONS 15200 Series Installation, Setup & User Manual

Table of Contents

Advertisement

Chapter 3
Installation
Remove the dust plugs located on the inside of the SCU SC-to-SC adapters.
Step 10
Step 11
Perform the following for each SC connector on the CFM fiber:
a.
Remove the dust cap from the SC connector on the CFM fiber. Do not remove the dust cap on the
MU connector of the CFM fiber.
b.
Clean and inspect each SC connector on the fiber.
Step 12
Connect the CFM fiber to the A- and B-side SC-to-SC adapters in accordance with the labels on the
cables.
channel.

Figure 3-38 CFM for an unprotected channel (100/0 or 0/100)

Figure 3-39 CFM for a protected channel (90/10, 10/90, or 50/50)

78-13765-01
Figure 3-38
shows a CFM for an unprotected channel;
Figure 3-40
through
Figure 3-44
B
Figure 3-39
show the connection information for each configuration.
Cisco ONS 15200 Installation, Setup, and Test Manual
shows a CFM for a protected
3-49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ons 15201Ons 15252

Table of Contents