Safety notices

1. 1

Intended use

The Powerturn door drive is designed for the automatic opening and closing of single-action swing doors.
The Powerturn is designed solely for use
à in dry rooms,
à in entrances and interior areas of pedestrian traffic in commercial plants and public areas,
à in private areas.
The Powerturn
à may be used on escape and rescue routes
à must not be used on fire and smoke protection doors.
à must not be used for potentially explosive areas.
The Powerturn F
à is designed for use on fire or smoke protection doors.
à may be used on escape and rescue route doors.
à must not be used for potentially explosive areas.
Any improper use such as permanent manual operation, as well as any modification to the product, is not permitted.
Observe the "GEZE Product information for door closers".
1.2
Safety notices
à The mandatory installation, maintenance and repair work must be performed by properly trained personnel
authorised by GEZE.
à The country-specific laws and regulations are to be observed during safety-related tests.
à If unauthorised changes are made to the system, GEZE cannot be held liable in any way whatsoever for any
resulting damage, and the approval for use in emergency exits ceases.
à GEZE does not accept any warranty for combinations with third-party products.
à Furthermore, only original GEZE parts may be used for repair and maintenance work.
à The connection to the mains voltage must be made by a professional electrician. Perform the power connec-
tion and equipment earth conductor test in accordance with VDE 0100 Part 610.
à Use an on-site 10-A overload cut-out as the line-side disconnecting device.
à Protect the display programme switch against unauthorised access.
à In compliance with Machinery Directive 2006/42/EC, a risk analysis must be performed and the door system
identified in accordance with CE Marking Directive 93/68/EEC before the door system is commissioned.
à Observe the current status of directives, standards and country-specific regulations, especially:
à ASR A1.7 "Directives for doors and gates"
à DIN 18650 "Building hardware - Powered pedestrian doors"
à DIN EN 16005 "Power operated pedestrian doorsets – Safety in use – Requirements and test methods"
à DIN VDE 0100-600: "Installation of low-voltage systems; Part 6: Tests"
à DIN EN 60335-2-103, DIN 18263-4
à Accident-prevention regulations, especially BGV A1 "Principles and prevention" and BGV A3 DA Implemen-
tation instructions for the accident prevention regulations "Electrical systems and equipment"