Chapter 2
CAUTION:
When reinstalling the delivery roller 1/2 unit, position it with the pressure
arms [4] on its reverse side in the holes [5] of the spine unit. If it is difficult
to position the delivery roller 1/2 unit, turn the spine drive pulley [6]
manually to move the spine unit.
5) Pull out the connector [1], remove the reuse band [2], and free the sensor
harness [4] from the edge saddle [3].
[1]
[3]
2-24
[4]
[5]
[6]
F-2-103
[2]
[3]
[4]
F-2-104
6) Turn the spine bending drive pulley [1] by a hand to move the spine bend-
ing unit (left) [2] towards the left side. Remove the four screws [3], and
then remove the spine bending unit (left).
CAUTION:
Install the spine bending unit (left) [2] to keep it in parallel with the transport
roller 4/5 unit [4].
[3]
7) Remove the rack mount [1].
- Support plate [2]
- 5 Screws [3]
[1]
[2]
[1]
[2]
F-2-105
[3]
[3]
[3]
[3]
F-2-106
[4]
[3]

Advertisement