Vacuum / Low Pressure Operation - Festo MPA-FB Series Manual

Valve terminal with mpa-s pneumatics
Hide thumbs Also See for MPA-FB Series:
Table of Contents

Advertisement

3. Installation

3.4.5 Vacuum / low pressure operation

Valve plates
Pressure zone with
vacuum or
low−pressure supply
1)
via connection 1
Pressure zone with
over pressure supply
via connection 1
1)
The valve plates with Ident. code D, H, K, N and I are not suitable for vacuum or low−pressure
operation if they are supplied via connection 1
2)
in accordance with diagrams in appendix A, Fig. A/2
3)
in accordance with diagrams in appendix A, Fig. A/1
Tab. 3/2:
Valve plates
Festo P.BE−MPA−EN en 0802c
Note
The 2x2/2−way valves with Ident. code D, I and the
2x3/2−way valves with Ident. code N, K, H are not suitable
for vacuum or low pressure operation if they are supplied
via connection 1.
Operate these valves in a separate pressure zone.
·
The operating pressure for this pressure zone must be
·
set in accordance with the diagram in Fig. A/1.
If valves are used for switching vacuum, filters must be
used in the suction line in order to avoid functional
damage due to dirt.
The following conditions must be fulfilled before you can
operate your MPA−S valve terminal at supply connection 1
with vacuum or low pressure between −0.9
The pilot control of the valve solenoid coils is operated
with external closed−loop regulated pilot air.
The valve terminal is fitted with the following valve plates
and, in some cases has further pressure zones.
The pressure zone must be fitted only with the following valve plates:
5/2−way valve, single−solenoid (Ident. code M)
5/2−way valve, double−solenoid (Ident. code J)
5/3−way valves (Ident. codes B, E and G)
3/2−way valve (Ident. code W and X) see
The pressure zone can also be fitted with the following valve plates:
3)
2x3/2−way valves (Ident. code H, K and N)
2x2/2−way valves (Ident. code D and I), see also the following note
3 bar:
2)
and the following note
3−19