Valve terminals MPA-S
Key features – Pneumatic components
5/3-way valve
Code
Circuit symbol
B
G
E
1)
If neither solenoid coil is energised, the valve moves to its mid-position by means of spring force.
If both coils are energised at the same time, the valve remains in the previously assumed switching position.
3/2-way valve
Code
Circuit symbol
W
X
2017/12 – Subject to change
Width
Description
[mm]
• Mid-position pressurised
10,

• Mechanical spring return

20

• Reverse operation

• Operating pressure –0.9 ... +10 bar
• Mid-position closed
10,
• Mechanical spring return
20
• Reverse operation
• Operating pressure –0.9 ... +10 bar
• Mid-position exhausted
10,
• Mechanical spring return
20
• Reverse operation
• Operating pressure –0.9 ... +10 bar
Width
Description
[mm]
• Single solenoid
10,

• Normally open

20
• External compressed air supply
• Pneumatic spring return
• Reverse operation
• Operating pressure –0.9 ... +10 bar
Compressed air (–0.9 ... +10 bar) supplied at working port 2
can be switched with both internal and external pilot air supply.
• Single solenoid
10,

• Normally closed

20
• External compressed air supply
• Pneumatic spring return
• Reverse operation
• Operating pressure –0.9 ... +10 bar
Compressed air (–0.9 ... +10 bar) supplied at working port 4
can be switched with both internal and external pilot air supply.