Connection
Fan connection 3-phase
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
RLS0782
Clamping area cable gland 7 ... 10 mm
Fig.8-8:
Fan connection 3-phase with protection switch
The activation of the fan units is done via the adjustable motor protection de‐
vice.
The activate principle of the motor protection switch is based on the fact that
the motor current-carrying bimetal trip heats up faster than the motor winding
and it separates this from the mains before critical temperature values are
reached.
The motor protection switches are adjusted to the rated current of the fan
unit. Heed when selecting the motor protection switch that the adjustable
range must agree with the rated current of the fan unit.
DOK-SYTROX-MPA01******-IT02-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPA01