Bosch Rexroth Sytronix MPA01 Operating Instructions Manual page 46

Motor-pump unit
Table of Contents

Advertisement

44/123
Bosch Rexroth AG
Assembly
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
For screw connections use screw lock, e.g. Loctite 243 when proceeding the
following working steps 1 to 3.
1. Screw on pump on adapter flange.
Screw the pump 1 in the required orientation (T, 1 (45°), R, 2 (135°), B,
3 (225°), L or 4 (315°) with the screws 1.1 and washers 1.2 on the
adapter flange 2 (tightening torque 87 Nm).
S
Suction port (figured option = B)
Fig.7-3:
Pump assembly mounting direction
In assembled state, the leakage hole (A) must be at the bottom that es‐
caping oil can flow out.
2. Mount pump foot
This mounting step is not necessary in design without pump foot 3.
Fasten the optional pump foot 3 with the screws 3.1, washers 3.2 and
nut 3.3 on the adapter flange (tightening torque 87 Nm).
3. Mount the motor
Use sufficiently measured lifting tools.
NOTICE
Carefully join the motor shaft and pump shaft, aligning without being
jammed. Strikes onto motor or pump can cause damage and are there‐
fore not allowed.
Insert the motor (4) in the required orientation (N, R or L) and the pump
group (1), (2), (3) in vertical position. Screw the motor (4) with the
screws (4,1) and washers (4.2) on the adapter flange (tightening torque
87 Nm).
Fig.7-4:
Motor assembly direction
DOK-SYTROX-MPA01******-IT02-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPA01
Damage by improper assembly opera‐
tion!

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth sytronix svp 70 series

Table of Contents