Rexroth Sytronix SvP 70xx Motor-Pump Unit MPA01
10.4.3

First Commissioning

Manual bleeding of the pump
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Check the suction line for tight assembly.
Make sure that the direction of rotation of the motor complies with the
direction of rotation of the pump.
1
Bleed part internal gear pump (M)
Fig.10-1:
Bleed part PGx
Proceed as follows to commission the internal gear pump PGH/PGM:
CAUTION
Slipping may cause serious injuries. When removing shaft protection, protec‐
tive plugs and flange covers, residual oil may leak at zero pressure.
Immediately absorb leaking residual oil.
WARNING
Before each commissioning, always check the lines for wear and/or
damage.
Wear protective gloves, protective goggles and suitable working clothes.
Immediately consult a doctor if there is nevertheless contact between
the hydraulic fluid and your eyes or your skin.
Pre-fill the pump with filtered fluid. Depending on the installation posi‐
tion, filling can be performed via the suction, pressure or measurement
port. For information regarding a suitable connection, please refer to the
operating instruction of the system.
Bleed the pump. For information on how to bleed the internal gear
pump, please refer to the operating instruction of the system. If no
switchable or automatic bleeding is provided, you must bleed the pump
manually.
Bosch Rexroth AG
Slip hazard!
Risk of intoxication and injury due to the leak‐
ing hydraulic medium! Contact with hydraulic
fluids causes health hazards (e.g. eye inju‐
ries, skin lesions, intoxication in case of inhal‐
ing).
71/123