Rexroth Sytronix SvP 70xx Motor-Pump Unit MPA01
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Fig.8-3:
Connecting the power and encoder cables
Connection
Designation
mm²
Clamp power U1, V1,
0.5 ... 16.0
W1
Clamp
temperature
0.25 ... 2.5
sensor
Stud
for
PE
and
M8
shield
Ring terminal for PE
M8
Ring
terminal
for
M8
shield power
Ring
terminal
for
M3
shield encoder
Tab.8-3:
Connection screws terminal box
Connect the power cable
Insert the ready-made power cable into the terminal box and tighten the
cable gland with the specified torque.
Do protective conductor and shield connection and tighten them with the
specified torque. Observe correct design of combined grounding con‐
nector and shield connector according to
(electrical connection)" on page
Connect power wires and tighten with the specified torque.
Plug the cable ties for temperature and engage.
Connect the encoder cable
Insert the ready-made encoder cable into the terminal box and tighten
the cable gland with the specified torque.
Do shield connection and tighten with the specified torque.
Plug the encoder and engage.
Bosch Rexroth AG
Stripping length
Tightening torque
mm
Nm
12
1.5 ... 1.8
7
0.5 ... 0.6
-
13.0
6 ... 8
6.0
6 ... 8
6.0
6 ... 8
1.3
fig. 8-2 "Mounting instruction
54.
55/123
Connection