Connect Motor-Pump Unit Electrically (Frame Size M11) - Bosch Rexroth Sytronix MPA01 Operating Instructions Manual

Motor-pump unit
Table of Contents

Advertisement

52/123
Bosch Rexroth AG
Connection
MPA-Type
MPA01-PGH__-NN-___-M11____-S3F-_N
MPA01-PGH__-NN-___-M11____-S3A-_N
MPA01-PGH__-NN-___-M13____-S3E-_N
8.3

Connect Motor-Pump Unit Electrically (Frame size M11)

LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Encoder Cables
HCS02.1.E-W0054
HCS02.1E-W0070
HMS01.1N-W0036
HCS03.1E-W0070
HMS01.1N-W0054
HMS01.1N-W0070
Tab.8-2:
Ready-made encoder cables
The order designation of ready-made cables consist of cable number and
length (e.g. RKL0071/010.0 for a cable length of 10.0 m).
WARNING
Work required on the electric system may only be carried out by skilled elec‐
tricians. Tools for electricians (VDE tools) are absolutely necessary.
Prior to commencing work:
1. Isolate (even auxiliary circuits).
2. Protect the system or plant against restart.
3. Ensure de-energization.
4. Ground and short-circuit.
5. Cover or shield any adjacent live parts.
Before starting to work, check with an appropriate measuring device whether
parts of the system are still under residual voltage (e.g. caused by capacitors,
etc.). If yes, wait until these parts have discharged.
WARNING
While the rotor is rotating, motors with permanent magnet ex‐
citation create a voltage > 60 V at the motor connections.
All work must be carried out at motor standstill.
An operation of motors is only allowed with respective converters. Direct con‐
nection on the three-phase current is not allowed and can lead to damage of
the motor.
NOTICE
Installed components (e.g., KTY84, encoder) may contain
electrostatic sensitive devices (ESD).
Observe ESD safety measures.
DOK-SYTROX-MPA01******-IT02-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPA01
HCS- / HMS-Type
HCS03.1E-W0100
HCS03.1E-W0150
HMS01.1N-W0110
HCS03.1E-W0210
HMS01.1N-W0150
HMS01.1N-W0210
HMS01.1N-W0300
RKG0047
RKG4200
Danger! Electric voltage! Operations in the vi‐
cinity of live parts are extremely dangerous.
High electrical voltage! Danger to life, risk of
injury due to electric shock.
Never touch the connection points of electro‐
static sensitive devices!
HCS04.2E-W0350

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth sytronix svp 70 series

Table of Contents