Transport and Storage
6.6
Storage Times
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
NOTICE
●
Protect the products from dampness and corrosion.
●
Store them only in rainproof and dry rooms.
Before storage, discharge the liquid coolant from liquid-cooled
motors to avoid frost damage.
Additional measures must be taken on commissioning to preserve proper
functioning – irrespective of the storage time which may be longer than the
warranty period of our products. However, this does not involve any
additional warranty claims.
Motors
Bearing time / months
Measures for commissioning
> 1
> 12
> 60
●
●
●
Control all parts to be free of damage.
●
●
Check all electrical contacts to be free from corrosion.
Let the motor run in without load for one hour at 800 ... 1,000
●
●
Upm. In the case of a mounted pump, ensure that the pump does
not run dry.
Measure the insulation resistance. Dry the winding at a value of <
●
●
1kOhm per volt rated voltage.
●
Exchange bearings.
●
Exchange encoders.
Tab.6-5:
Measures before commissioning motors that have been stored over a
prolonged period of time
Cables and Connectors
Bearing time / months
Measures for commissioning
> 1
> 12
> 60
●
●
●
Control all parts to be free of damage.
●
●
Check all electrical contacts to be free from corrosion.
Visually inspect the cable jacket. Do not use the cable if you de‐
●
tect any abnormalities (squeezed or kinked spots, color devia‐
tions, ...).
Tab.6-6:
Measure before commissioning cables and connectors that have been
stored over a prolonged period of time
DOK-SYTROX-MPA01******-IT02-EN-P
Rexroth Sytronix SvP 70xx Motor-Pump Unit MPA01
Damage due to moisture and humidity!