Calibrate the milk foam temperature
Tools needed:
• Electronic thermometer with fast response sensor
1. Fix the fast response temperature sensor
in the milk outlet.
2. Place a collection tray under the outlet.
3. Select the milk foam button [B].
4. Start the calibration [A]. Milk fl ows from the outlet
5. Set the advised milk temperature with
the + and - buttons.
6. Stop the calibration [A]
Calibrate the warm milk temperature
7. Start the warm milk calibration and set the
advised milk temperature.
8. Select the warm milk button [C].
9. Start the calibration [A].
Milk fl ows from the outlet
10. Set the advised milk temperature with
the + and - buttons.
11. Stop the calibration [A].