Error Codes Imatch Remote Control - Kalfire G Series Installation Instructions Manual

Balanced-flue gas fires
Hide thumbs Also See for G Series:
Table of Contents

Advertisement

7.2.2 Error codes iMatch remote control

Error code
Cause
Entire display
Flat battery
flashing
Almost flat battery
NOLK 0 in the
middle of the
Control error
display
No communication
between remote
NOLK
control and fireplace
top left corner
(for example in case
of the display
of a new remote
control)
Temperature of the
02F
circuit board is too
high
No mains voltage
04F
supply (two-way
switch only)
06F
No communication
or
between remote
control and fireplace
flashing
31
Solution
Replacing battery.
Replacing battery.
Briefly press >NOLK< will appear in the top left corner of the display.
Synchronising remote control:
1. Open the hatch of the technical unit and carefully remove the automatic burner relay
so it is easily accessible.
2. Remove the batteries from the remote control and press (hereby discharging the
remote control). Next, replace the batteries into the remote control.
3. Isolate the automatic burner relay from power for 20 seconds, this will stimulate
the synchronisation speed. Supply power back to the cable.
The entire light will start flashing (once per second). Should the gas fire is provided
with a hybrid function and/or NSG: detach the HCB cable from the automatic burner
relay.
4. Press
on the remote control until >NOLK 0< appears on the display.
Next, release
.
5. In case >NOLK 1< or >LINK 1< appear, press
6. Press the black button in the automatic burner relay until the yellow light continuously
stops flashing, then immediately release the black button. The yellow light will start
flashing rapidly now.
7. Immediately (within 10 seconds) press
>LINK<starts flashing on the display.
8. Wait until >LINK 1< appears and release
9. Press
. The normal display with a stationary RF icon
synchronisation is successful.
10. Reconnect the HCB cable (if applicable).
11. Place the automatic burner relay back into the technical unit and close the hatch.
1. Turn off the fireplace for approximately 30 minutes.
2. Then turn on the fireplace.
3. In case the error reappears, there is insufficient ventilation in the chamber of the
fireplace.
Supply mains voltage.
In case the light on the automatic burner relay (in the technical unit) does not flash:
1. Check power supply on the mains (230VAC).
2. If this is correct, check/replace the VDC transformer and/or automatic burner relay.
In case the light on the automatic burner relay (in the technical unit) flashes:
1. Place the remote control as close to the fireplace as possible.
2. Briefly press
and wait approximately 60 seconds.
3. Check the transmission strength. See: Checking transmission strength page 24.
Carry out the following steps to check the transmission strength between the
fireplace and the remote control.
4. Check for objects that could jam the signal (for instance metal casings).
5. In case the signal keeps flashing -> synchronise
again until >NOLK 0< appears.
and hold it down until the word
.
will appear once the