Kalfire G Series Installation Instructions Manual page 91

Balanced-flue gas fires
Hide thumbs Also See for G Series:
Table of Contents

Advertisement

Gas
Gas
Connection
cat.
type
pressure
12H
G20
20mbar
12E
G20
20mbar
G25
25mbar
12E+
G20
20 mbar
I2(43.46 –
45.3 MJ/m3
G25.3 25mbar
(0°C))/ /I2K
I2ELL
G20
20mbar
I2ELL
G25
20mbar
G30
28-30mbar
13+
G31
37 mbar
13B/P
G30
28-30 mbar
13B/P
G30
50 mbar
Gas
Connection
Gas type
cat.
pressure
12H
G20
20mbar
12E
G20
20mbar
G25
25 mbar
12E+
G20
20mbar
I2(43.46 –
45.3 MJ/m3
G25.3
25 mbar
(0°C))/ /I2K
I2ELL
G20
20mbar
I2ELL
G25
20mbar
G30
28-30mbar
13+
G31
37 mbar
13B/P
G30
28-30 mbar
13B/P
G30
50 mbar
Gas
Connection
Gas type
cat.
pressure
12H
G20
20mbar
12E
G20
20mbar
G25
25mbar
12E+
G20
20mbar
I2(43.46 –
45.3 MJ/m3
G25.3
25 mbar
(0°C))/ /I2K
I2ELL
G20
20mbar
I2ELL
G25
20mbar
G30
28-30 mbar
13+
G31
37 mbar
13B/P
G30
28-30 mbar
13B/P
G30
50 mbar
91
KALFIRE GP 60/79F, GP65/75C, GP70/75S
Load
Orifice
Injector
Use
MAX (Hi)
Code
Code
m³/h
kW (input)
(mm)
(mm)
10.3
1.09
3.5
3x1.6 + 0.8
10.3
1.09
3.5
3x1.6 + 0.8
10.3
1.09
3.5
3x1.6 + 0.8
10.3
1.09
3.5
3x1.6 + 0.8
10.3
1.3
3.9
3x1.6 + 0.8
10.3
1.09
3.5
3x1.6 + 0.8
8.7
1.07
3.5
3x1.6 + 0.8
8.9
0,28
2.0
3x1.0 + 0.5
8.7
0.35
2.0
3x1.0 + 0.5
8.9
0.28
2.0
3x1.0 + 0.5
8.9
0.28
2.0
3x1.0 + 0.5
KALFIRE GP75/59F, GP80/55C, GP85/55S
Load
Orifice
Injector
Use
MAX (Hi)
Code
Code
m³/h
kw (input)
(mm)
(mm)
10.5
1.1
3.1
2x1.6 +1.75
10.5
1.1
3.1
2x1.6 +1.75
10.5
1.1
3,1
2x1.6 +1.75
10.5
1.1
3.1
2x1.6 +1.75
10.4
1.28
3.4
2x1.6 +1.75
10.5
1.1
3.1
2x1.6 +1.75
9.1
1.12
3.1
2x1.6 +1.75
6.7
0.21
1.7
6.7
0.21
1.7
7.1
0.22
1.5
KALFIRE GP80/54T / GP85/50R
Load
Orifice
Injector
Use
MAX (Hi)
Code
m³/h
kw (input)
(mm)
10.5
1.06
3.2
3x1.6 + 0.8
10.5
1.06
3.2
3x1.6 + 0.8
10.5
1.06
3.2
3x1.6 + 0.8
10.5
1.06
3.2
3x1.6 + 0.8
10.5
1.25
3.9
3x1.6 + 0.8
10
1.06
3.2
3x1.6 + 0.8
10
1.06
3.9
3x1.6 + 0.8
6.7
0.29
2.0
3x1.0 + 0.5
8.7
0.35
2.0
3x1.0 + 0.5
6/7
0.29
2.0
3x1.0 + 0.5
7.1
0.29
2.0
3x1.0 + 0.5
Burner pressure
Burner pressure
maximum
minimum
mbar
mbar
14.2
4.6
14.2
4.6
14.2
4.6
14.2
4.6
19.7
4.4
14.2
4.6
14
4.6
18.5
8.2
20.0
9.3
18.5
7.6
18.5
8.2
NOX-class: 4
Burner pressure
Burner pressure
maximum
minimum
mbar
mbar
11.9
6.1
11.9
6.1
11.9
6.1
11.9
6.1
15.9
6.8
11.9
6.1
12
6.4
1.2
6.9
3.2
1.2
5.5
3.2
1.2
5.7
3.2
NOX-class: 4
Burner pressure
Burner pressure
Code
maximum
minimum
(mm)
mbar
mbar
12.7
9.2
12.7
9.2
12.7
9.2
12.7
9.2
19.7
13.2
12.7
9.2
19.7
13.2
6.5
17.2
9.3
17.2
6.5
17.2
6.5
NOX-class: 5
Power
Return on
Energy
maximum
investment
efficiency
kw (output)
class
class (sc)*
7.9
2
D
7.9
2
D
7.9
2
D
7.9
2
D
7.8
2
D
7.9
2
D
6.5
22
D
6,6
2
D
6,4
2
D
7.9
2
D
7.9
2
D
Power
Return on
Energy
maximum
investment
efficiency
kW (output)
class
class (sc)*
8.7
1
C
8.7
1
C
8.7
1
C
8.7
1
C
8
2
D
8.7
1
D
7.4
2
D
D
4.3
2
D
4.2
2
D
4.2
2
D
Power
Return on
Energy
maximum
investment
efficiency
kW (output)
class
class (sc)*
7.9
2
D
7.9
2
D
7.9
2
D
7.9
2
D
7.7
2
D
7.9
2
D
7.7
2
D
6.1
2
D
6,4
2
D
6.1
2
D
6.1
2
D
Energy
efficiency
class (lc)**
A
A
A
A
A
A
A
B
B
B
B
Energy
efficiency
class (lc)**
A
A
A
A
A
A
A
A
A
A
A
Energy
efficiency
class (lc)**
A
A
A
A
A
A
A
B
B
B
B