ADC 600F User Manual

Megabit modem
Hide thumbs Also See for 600F:
Table of Contents

Advertisement

Megabit Modem
Megabit Modem
Megabit Modem 400F, 500L, 600F, and
700F User Manual
Version 3.2.X
Catalog Number
MMD4090I1 Issue 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 600F and is the answer not in the manual?

Questions and answers

Summary of Contents for ADC 600F

  • Page 1 Megabit Modem Megabit Modem Megabit Modem 400F, 500L, 600F, and 700F User Manual Version 3.2.X Catalog Number MMD4090I1 Issue 1...
  • Page 2 Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
  • Page 3 IP addresses used in this manual are for example only. You will acquire your own addresses from the service provider and your information services coordinator to configure the Megabit Modem 400F, 500L, 600F, and 700F. However, you will use the IP address specified in “Accessing the Modem Web Pages” on page 27 600F, and 700F from a Web browser.
  • Page 4: Fcc Class B Compliance

    Consult the dealer or an experienced radio/TV technician for help. This product meets all safety requirements per UL-1950 standard. This product meets all EMC and safety requirements per EN 300 386-2 and IEC 950 (EN60950). Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 5: Table Of Contents

    Chapter 4: Setting Up For Configuration ...23 Setting Up the PC To Configure the Modem ...24 Configuring a Web Browser... 25 Accessing the Modem Web Pages...27 Saving the Configuration...28 Megabit Modem 400F, 500L, 600F, and 700F User Manual Table of Contents...
  • Page 6 Configuring the WAN PPP Sessions ...53 Add a PPP over ATM WAN Session ...54 Modify a PPP over ATM WAN Session...57 Delete a PPP over ATM WAN Session ...57 Configuring the LAN...58 Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 7 Using the RS-232 Management Port... 80 Setting Up the PC to Request an IP Address...83 Troubleshooting...84 Chapter 10: Technical Reference ... 85 Transmission on the Wide Area Network ... 85 Megabit Modem 400F, 500L, 600F, and 700F User Manual Table of Contents...
  • Page 8 Compliance ...98 RFCs ...98 MIBs ...98 Rate vs. Reach...99 Hardware...100 Installation Kit ...100 Connector Pinouts ...101 Appendix B: Technical Assistance and Returns ...103 Technical Support ...103 World Wide Web ...103 viii Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 9 Advance Replacement ... 103 Billing ... 104 Returns... 105 Appendix C: Configuration Worksheets ... 107 Appendix D: Glossary ... 117 Megabit Modem 400F, 500L, 600F, and 700F User Manual Table of Contents...
  • Page 10 Table of Contents Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 11: Chapter 1: About The Product

    In addition, the LEDs on the modem front panel provide continual status at-a-glance for network and modem connections. The following sections list the Megabit Modem 400F, 500L, 600F, and 700F features and applications. Megabit Modem 400F, 500L, 600F, and 700F User Manual BOUT ®...
  • Page 12: Megabit Modem 400F

    • contains an embedded SNMP agent • operates as a DHCP server • supports NAT (including NAPT) and DNS See the illustration on the next page for an application example. 400F Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 13 Chapter 1: About The Product Business Internet Access ADSL Internet 400F Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 14: Megabit Modem 500L

    RFC 2364 PPP over ATM (AAL5) • supports up to 8 sessions • contains an embedded SNMP agent • operates as a DHCP server • supports NAT (including NAPT) and DNS 500L Microfilter ADSL 500L Megabit Modem 400F, 500L, 600F, and 700F User Manual Internet...
  • Page 15: Megabit Modem 600F

    EGABIT ODEM The Megabit Modem 600F is a high-performance ADSL modem designed for power users. It offers these features: • supports full-rate ADSL and G.lite • offers rates up to 7.552 Mbps downstream/928 kbps upstream for full rate • offers rates up to 1.5 Mbps downstream/512 kbps upstream for G.lite •...
  • Page 16: Megabit Modem 700F

    • contains an embedded SNMP agent • operates as a DHCP server • supports NAT (including NAPT) and DNS See the illustration on the next page for an application example. 700F Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 17 Chapter 1: About The Product Large Business Internet Access ADSL Internet 700F Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 18 Megabit Modem 700F Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 19: Chapter 2: What You Need To Start

    This chapter identifies the preparations and prerequisites for installing the Megabit Modem 400F, 500L, 600F, and 700F. Before installing the modem, verify that: • The contents of the package are accurate as described on this page. • Your system meets the requirements for connecting to and configuring the modem (see “Requirements For Your System”...
  • Page 20: Requirements For Your System

    Web browser installed such as Netscape • Ethernet hub (optional) EQUIREMENTS Before installing the Megabit Modem 400F, 500L, 600F, and 700F, you must: • select a location to install the modems as described in the section below • identify requirements to connect phones as described in the section...
  • Page 21: Flat-Surface Mount

    Place the modems on a flat surface, such as on a table or in a rack. L IN Minimum 1-inch clearance Minimum 1-inch clearance Megabit Modem 400F, 500L, 600F, and 700F User Manual L IN L IN Chapter 2: What You Need To Start...
  • Page 22: Wall Mount

    Observe the minimum dimensions between multiple modems (shown in the illustration) to ensure sufficient ventilation for heat dissipation Mount the Megabit Modem on a wall using the two screws included with the modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 23: Phone Service

    PPP system mode, Login Name and Login Password (specified for each session) For more information about the configuration choices listed above, see Reference” on page Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 2: What You Need To Start ERVICE...
  • Page 24: What You Will Choose

    TFTP server. Power Cable The Megabit Modem 400F, 500L, 600F, and 700F are available with a variety of power supplies and power cords. When you order your modem, choose one of the following as the last number...
  • Page 25: Chapter 3: Installing The Modem

    Adapter assembly connects to a DB-9 connector on the PC. Then, one RJ-45 connector installs in the adapter and the other connector into the console port on the modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual “Requirements For The Installation Site” Installation Kit...
  • Page 26: Attaching The Feet

    Attaching the Feet TTACHING THE Attach each of the four adhesive-backed rubber feet to a footprint recess on the bottom of the modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 27: Chapter 3: Installing The Modem

    For connection to devices such as a PC MDI-X For connection to devices such as a hub 10/100BASE-T MDI-X Megabit Modem 400F, 500L, 600F, and 700F User Manual WITCH RS232 MGMT Chapter 3: Installing the Modem ADSL POWER...
  • Page 28: Installing Cabling

    PC, hub or other network device Wall jack with DMT ADSL service To power outlet Megabit Modem Switch 10/100BASE-T port RS-232 MGMT port (600F and 700F only) I - X Megabit Modem 400F, 500L, 600F, and 700F User Manual ADSL port Power connector...
  • Page 29 If you need pinouts for the ADSL and 10/100BASE-T connectors, see page 101. For information on how to use the RS-232 management port for maintenance, see “Using the RS-232 Management Port” on page Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 3: Installing the Modem “Connector Pinouts” on...
  • Page 30: Setting Up Adsl Service

    ADSL margin is at or above the value set by the service provider. ADSL margin is below the value set by the service provider. Telephone receiver is off hook. Telephone receiver is on hook. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 31: Connecting Phone Service

    ONNECTING HONE The Megabit Modem 400F, 500L, 600F, and 700F modem provide full support for the ITU standard G.hs, G.dmt, and G.lite. In the traditional ADSL deployment, POTS splitters are required to separate data transmission from phone service. In this case, the service provider will supply you with a splitter.
  • Page 32 Connecting Phone Service Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 33: Chapter 4: Setting Up For Configuration

    ETTING Set up a PC and a Web browser to configure the Megabit Modem 400F, 500L, 600F, and 700F. This chapter provides the set up procedures, then shows you how to access and navigate the Megabit Modem Web pages. The configuration process flow is shown below.
  • Page 34: Setting Up The Pc To Configure The Modem

    Network TCP/IP and skip to step 5. Otherwise, select The default LAN IP address is 192.168.0.1. Use an IP Megabit Modem 400F, 500L, 600F, and 700F User Manual ODEM icon. Obtain an IP Specify an IP address...
  • Page 35: Chapter 4: Setting Up For Configuration

    Open your Web browser. Click Edit Preferences From Category, select From Category, select Click to close the Preferences window. Megabit Modem 400F, 500L, 600F, and 700F User Manual ROWSER to open the Preferences dialog. Advanced , click Cache, then select Advanced...
  • Page 36 Internet Options dialog. section of the dialog, click , then click tab, then click LAN Settings to open the LAN Settings dialog. Use a proxy server Megabit Modem 400F, 500L, 600F, and 700F User Manual Settings box.
  • Page 37: Accessing The Modem Web

    If the Megabit Modem is in “Bridging/Routing” mode, it displays this page: Megabit Modem 400F, 500L, 600F, and 700F User Manual ODEM AGES Location Bar field of the Web browser (as shown below), then press Location Bar http://192.168.0.1/index.htm...
  • Page 38: Saving The Configuration

    • reset the modem to restore the factory default values on Apply . However, there are other Menu system general general general general page 29 page 30 page 31 Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 39: Saving The Configuration To Nvram

    Locate Apply at the bottom of the dialog. Click to open the Apply confirmation dialog. Click to reset the modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 4: Setting Up For Configuration the changes are automatically saved...
  • Page 40: Resetting The Modem

    From the system menu, click Click Reset Unit. Click Proceed to reset the modem. general to open the General System window. Megabit Modem 400F, 500L, 600F, and 700F User Manual page 28...
  • Page 41: Resetting The Modem To Factory Defaults

    When you click Proceed to return to factory default values, the modem automatically resets. Click Proceed to return to factory default values. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 4: Setting Up For Configuration page 32 general to open the General System window.
  • Page 42 Primary DNS Enabled Gateway Dynamic Static NAT Entries (private, proxy, and remote) 0.0.0.0 IP Addresses Ports blank field Protocol 0.0.0.0 Megabit Modem 400F, 500L, 600F, and 700F User Manual Default Value Not enabled 0.0.0.0 255.255.255.0 public public private 192.168.0.1 255.255.255.0 Enabled 192.168.0.2...
  • Page 43 Static Mac Address Entry MAC Address Source Port Dest Port Static Route Entry (IP Address, IP Network Mask, Gateway IP Address) Megabit Modem 400F, 500L, 600F, and 700F User Manual Default Value Parameter Bridge/Router RFC 1483 Not selected Spanning Tree blank field...
  • Page 44 Saving the Configuration Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 45: Chapter 5: Configuring System Settings

    48 either PPP over ATM or 1483 Bridging/Routing (for Megabit Modem 700F only) Unless specified otherwise, configuration parameters shown in this section are for example only. Megabit Modem 400F, 500L, 600F, and 700F User Manual YSTEM page 36 page 38 for sessions between the modem and the service provider;...
  • Page 46: Defining Tftp Parameters

    This may or may not be required depending on the TFTP server configuration. (Example: c:\download\) File Name The full name of the updated software (example: tiger.bin) ARAMETERS Megabit Modem 400F, 500L, 600F, and 700F User Manual page 77 for procedures on...
  • Page 47 “tiger.bin” has been placed directly inside the shared directory (not in a subdirectory of the shared directory). Therefore, the File Path should be left blank. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 5: Configuring System Settings of the updated software file.
  • Page 48: Defining Snmp Parameters

    The authentication string for viewing the modem statistics and changing parameters. The SNMP management station must have the same string in its configuration. The default is private. page 39 Megabit Modem 400F, 500L, 600F, and 700F User Manual and are case sensitive. If you...
  • Page 49 , and read-write community string set to Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 5: Configuring System Settings trapit , read-only community string set to...
  • Page 50: Defining Static Nat Entries

    From the system menu, click NAT E NTRIES page 87 static NAT table to open the Static NAT Table window. Megabit Modem 400F, 500L, 600F, and 700F User Manual Static NAT for more information on NAT...
  • Page 51 Click to accept the changes or Megabit Modem 400F, 500L, 600F, and 700F User Manual of the device on the LAN side of the modem. of the device on the LAN side of the modem. that is mapped to the Private IP Address.
  • Page 52: Configuring Static Mac Entries

    Select of the address to be changed. MAC E TATIC NTRIES static MAC table to open the Static MAC Table window. static MAC table to open the Static MAC Table window. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 53: Delete A Static Mac Entry

    Click Select of the address to be deleted. Click Delete to remove the selected address. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 5: Configuring System Settings static MAC table to open the Static MAC Table window.
  • Page 54: Configuring Static Routes

    Click to change the existing data to the list. TATIC OUTES static route table to open the Static Route Table window. to open the Static Route Table window. static route table Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 55: Delete A Static Route

    Click Select of the static route to be deleted. Click Delete to remove the selected route. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 5: Configuring System Settings static route table to open the Static Route Table window.
  • Page 56: Configuring System Security

    Example: The illustration above shows the modem configuration to allow only the station with the IP address 192.168.0.3 to access the modem on the same LAN. YSTEM ECURITY general to open the General System window. Megabit Modem 400F, 500L, 600F, and 700F User Manual 0.0.0.0 in the...
  • Page 57: Rs-232 Mgmt Port

    You can change the Admin IP Address for the 600F and 700F by physically connecting to the RS-232 MGMT port. RS-232 MGMT Port The RS-232 MGMT Port allows access to several parameters such as the LAN IP settings, Admin IP Address, and modem reset.
  • Page 58: Selecting The System Mode Of Operation

    The Megabit Modem 400F operates only in Bridge/Router RFC 1483 mode, while the Megabit Modem 500L and 600F operate only in PPP over ATM mode. This section provides procedures to select the system mode. Then, use the section “Saving the Configuration”...
  • Page 59 Click Apply At the Proceed message, click Click reset unit to reset the modem and activate the changes. At the System Reset message, click Proceed Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 5: Configuring System Settings...
  • Page 60 Selecting the System Mode of Operation Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 61: Chapter 6: Configuring Ppp Sessions

    Configuring the WAN PPP Sessions Configuring the LAN Assigning LAN Users to PPP Sessions Activating and Deactivating Sessions For these sessions, PPP runs over ATM virtual circuits (VCs). Megabit Modem 400F, 500L, 600F, and 700F User Manual PPP S ESSIONS Go to page:...
  • Page 62: Selecting Configuration Parameters

    Select PPP Over ATM as the of Operation Click Apply , then reset the modem. ARAMETERS How IP Address Acquired Dynamic Dynamic Fixed Fixed Fixed PPP M (700F O Mode Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 63: Configuring The Wan Ppp Sessions

    • 32 sessions for a 700F Access the WAN Connections Megabit Modem 400F, 500L, 600F, and 700F User Manual WAN PPP S page, you configure parameters that set up communication between page and use the following table for reference. Chapter 6: Configuring PPP Sessions...
  • Page 64: Add A Ppp Over Atm Wan Session

    Add a PPP over ATM WAN Session You add a PPP WAN session in the reference table and procedure to set up a session. PPP Over ATM WAN Configuration Megabit Modem 400F, 500L, 600F, and 700F User Manual window. Use the following...
  • Page 65 If enabled, the session is active and is ready to establish the PPP link. If disabled, the session is not active. Address Assignment Determines whether the session IP address is assigned by the service provider (Dynamic) or entered by the user (Fixed). Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 6: Configuring PPP Sessions...
  • Page 66 Click Refresh to update the connections window. to display the PPP Over ATM WAN Configuration cancel to cancel the set up of the session. Megabit Modem 400F, 500L, 600F, and 700F User Manual page.
  • Page 67: Modify A Ppp Over Atm Wan Session

    Click Refresh to update the WAN Connections window. Megabit Modem 400F, 500L, 600F, and 700F User Manual Port 1-32 to display the PPP Over ATM WAN Configuration page 55 connections to open the WAN Connections window.
  • Page 68: Configuring The Lan

    Primary DNS IP address of the primary Domain Name System (DNS) device that translates names into IP addresses. Default Gateway Default router set to the IP address of the LAN port. Megabit Modem 400F, 500L, 600F, and 700F User Manual general...
  • Page 69: Saving The Configuration

    Although you have submitted your new system settings, the parameters are not permanent until you write them to NVRAM. See to save to NVRAM. Megabit Modem 400F, 500L, 600F, and 700F User Manual Net Mask “Saving the Configuration” on page 28...
  • Page 70: Assigning Lan Users To Ppp Sessions

    500L. In addition, you can map 64 users to the sessions you configure for the 600F and 700F. For example, you could map two users to 32 configured sessions, 64 users to one configured session, or any combination you choose, up to a maximum of 64 users mapped to all the sessions you configure.
  • Page 71: Delete A User Assignment

    Select the user assignment to be deleted, then click the Click Delete to remove the selected user assignment. Megabit Modem 400F, 500L, 600F, and 700F User Manual user assignment to open the WAN User Assignment window. Select Chapter 6: Configuring PPP Sessions...
  • Page 72: Activating And Deactivating Sessions

    To activate the session, place a checkmark in the Session Enable To deactivate the session, clear the checkmark. Click to accept the changes. EACTIVATING connections box by clicking in it. Megabit Modem 400F, 500L, 600F, and 700F User Manual ESSIONS...
  • Page 73: Chapter 7: Configuring Bridging/Routing Sessions

    Setting Up the Bridging/Routing Mode (700F Only) Configuring the WAN Bridging/Routing Sessions Configuring the LAN Activating and Deactivating Sessions For these sessions, PPP runs over ATM virtual circuits (VCs). Megabit Modem 400F, 500L, 600F, and 700F User Manual ONFIGURING OUTING ESSIONS Go to page:...
  • Page 74: Setting Up The Bridging/Routing Mode (700F Only)

    To have all sessions, up to 32, as Bridging/Routing mode of operation, do the following: From the system menu, select general Select Bridge/Router RFC1483 Mode of Operation Click Apply , then reset the modem. RIDGING OUTING Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 75: Configuring The Wan Bridging/Routing Sessions

    Displays the connection state. Up - Session is up. Down - Session is down. Connecting - Session is setting up. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 7: Configuring Bridging/Routing Sessions WAN B RIDGING page, you configure parameters that set up communication between...
  • Page 76: Add A Bridging/Routing Wan Session

    The IP Net Mask address of the modem's WAN port. RIP Direction The direction the RIP routing information flows. RIP Version The version of the RIP protocol. WAN Port Configuration window. Use the Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 77 Click to create the session or click Click Refresh to update the connections window. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 7: Configuring Bridging/Routing Sessions to display the WAN Port Configuration cancel to cancel the set up of the session.
  • Page 78: Modify A Bridging/Routing Wan Session

    66 connections to open the WAN Connections window. edit to open the WAN Port Configuration Cancel Megabit Modem 400F, 500L, 600F, and 700F User Manual page for that for a description of parameters. page. to cancel any changes you made...
  • Page 79: Configuring The Lan

    The function of routing packets based on layer 3 headers. Enable Enables/Disables routing. RIP Direction The direction the RIP routing information flows. RIP Version The version of the RIP protocol. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 7: Configuring Bridging/Routing Sessions general...
  • Page 80: Saving The Configuration

    Although you have submitted your new system settings, the parameters are not permanent until you write them to NVRAM. See to save to NVRAM. Net Mask “Saving the Configuration” on page 28 Megabit Modem 400F, 500L, 600F, and 700F User Manual when you want...
  • Page 81: Activating And Deactivating Sessions

    To activate the session, place a checkmark in the Session Enable To deactivate the session, clear the checkmark. Click to accept the changes. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 7: Configuring Bridging/Routing Sessions EACTIVATING connections box by clicking in it. ESSIONS...
  • Page 82 Activating and Deactivating Sessions Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 83: Chapter 8: Viewing Statistics

    (“Viewing Network Statistics” on page ADSL S IEWING The Megabit Modem 400F, 500L, 600F, and 700F displays the status of the ADSL link. Resetting ADSL will close off the ADSL loop connection between the modem and the service provider. Active connections will disconnect.
  • Page 84 Shows the rate of data transmission in kilobits per second (kbps). From the adsl menu, click Monitor the ADSL Status. Click Refresh to update the statistics or status to open the ADSL Status window. Clear to clear the statistics. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 85: Viewing Network Statistics

    IEWING ETWORK The Megabit Modem 400F, 500L, 600F, and 700F display status for the LAN and WAN links. From the Main Menu , select LAN Statistics The Megabit Modem 400F, 500L, 600F, and 700F displays status for the LAN. View the following LAN information:...
  • Page 86: Wan Statistics

    Viewing Network Statistics WAN Statistics The Megabit Modem 400F, 500L, 600F, and 700F displays status for the WAN. View the following WAN information: Information Description Rx Packets The total number of packets received at the WAN interface. Tx Packets The total number of packets transmitted out the WAN interface.
  • Page 87: Chapter 9: Maintenance And Troubleshooting

    “Updating Software” on page 77 Megabit Modem 400F, 500L, 600F, and 700F. Through the RS-232 MGMT port on the Megabit Modem 600F and 700F, you can change the modem LAN port IP address and network mask, the default gateway IP address, and the IP...
  • Page 88 TFTP server (if necessary). Enter the File Name of the updated software file. page to configure the TFTP parameters. general to open the General System window. (subnet mask) for the TFTP server. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 89 Click Proceed to confirm the file transfer process. Wait for the file to download. 10 Click to restart the modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual to begin the file transfer. Chapter 9: Maintenance and Troubleshooting...
  • Page 90: Using The Rs-232 Management Port

    Connect the modem to a PC as shown below. PC, hub or other network device Wall jack with DMT ADSL service Switch 10/100BASE-T port RS-232 MGMT port (600F and 700F only) ADSL port I - X Megabit Modem 400F, 500L, 600F, and 700F User Manual Power connector...
  • Page 91 (1)Enter IP address (2)Enter IP network mask (3)Enter default gateway IP address (4)Enter IP Admin address (5)Reset modem (6)Change password (7)Logout > Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 9: Maintenance and Troubleshooting 3.0.0(1) 3.2.0 192.168.0.1 255.255.255.0 0.0.0.0...
  • Page 92 IP address for a device on the LAN that will manage the modem. Type to reset the modem after you change the LAN IP address and the LAN IP network mask. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 93: Setting Up The Pc To Request An Ip Address

    Obtain an IP address automatically Click to close the TCP/IP Properties window. Click to close the Network window. Click to restart the computer. Megabit Modem 400F, 500L, 600F, and 700F User Manual EQUEST AN window by clicking Start Settings icon. TCP/IP...
  • Page 94: Troubleshooting

    LEDs are not on on the WAN ADSL port. If, the SYNC LED is not on, contact your service provider. “Setting Up the PC To Configure in this table. Megabit Modem 400F, 500L, 600F, and 700F User Manual “PC or hub not...
  • Page 95: Chapter 10: Technical Reference

    DMT ADSL provides rate-adaptive transmission that allows the service provider to deliver you the best transmission rate determined by distance and line conditions. Megabit Modem 400F, 500L, 600F, and 700F User Manual EFERENCE ETWORK...
  • Page 96: Atm

    The VPI and VCI provide the virtual connection between the modem and the service provider. The VPI identifies the Virtual Path (VP) that transports ATM cells in a Virtual Channel (VC). The Megabit Modem 400F, 500L, 600F, and 700F has 32 VCs in the VP, which provides the 32 sessions.
  • Page 97: Chapter 10: Technical Reference

    IP address ranges can benefit from this operation, as the private IP addresses will remain the same when the public IP addresses are reassigned. Megabit Modem 400F, 500L, 600F, and 700F User Manual NCAPSULATION Chapter 10: Technical Reference...
  • Page 98: Mac Layer Bridging

    An example of the active topology is shown on algorithm partitions out the bridge from LAN A to LAN B, and creates the link from ENET2 to Bridge 5. page 89. In the example, the spanning tree Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 99 Spanning Tree to eliminate loops. Bridge 1 ENET 1 Bridge 4 Using Spanning Tree Protocol Bridge 1 ENET 1 Bridge 4 Megabit Modem 400F, 500L, 600F, and 700F User Manual Bridge 2 Bridge 3 Bridge 5 ENET 3 Loop-free Topology LAN A Bridge 2...
  • Page 100: Routing

    IP). VC-MUX allows only one protocol to run over the VC. The type of protocol must be negotiated between the modem and the service provider prior to the transmission. Because there is only one protocol allowed, the header is not required. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 101: Management Protocols

    The Internet Engineering Task Force (IETF) specifies standard MIBs for certain types of devices, ensuring any NMS can manage them. Additionally, vendors can issue proprietary MIBs for their devices to fit specific needs. Megabit Modem 400F, 500L, 600F, and 700F User Manual ROTOCOLS Chapter 10: Technical Reference...
  • Page 102: Mib And Trap Support

    Spanning Tree, and transparent bridging groups. The Spanning Tree MIB can only be accessed if the Spanning Tree protocol is enabled. • ADSL MIB • ATM MIB • ADC Agent MIB • ADC Tiger MIB Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 103: Dns Resolution

    Internet. Once you have selected and installed the TFTP server software, configure it to share a directory containing the binary files. To configure the Megabit Modem to access the TFTP server, see Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 10: Technical Reference Chapter 9 on page...
  • Page 104 TFTP Server Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 105: Appendix A: Specifications And Data

    Signal Format Connector ATM Adaptation Layer ATM Layer Cell Format Virtual Circuit type Maximum Virtual Circuits Megabit Modem 400F, 500L, 600F, and 700F User Manual PECIFICATIONS ADSL (Asymmetric Digital Subscriber Line) 7.552 Mbps 928 kbps 64 kbps 32 kbps increments...
  • Page 106: Encapsulation

    Implements a transparent learning bridge with a bridging table of 1024 entries. Learning Encapsulation Supports Logical Link Control (LLC) or VC-based multiplexing (RFC 1483). Spanning Tree Provides Spanning Tree support per IEEE 802.1d. Routing Bridging Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 107: Appendix A: Specifications And Data

    0.3 Amps NVIRONMENTAL Temperature 32° to 122 °F (0° to 50°C) Relative Humidity up to 95% non-condensing Altitude between -200 and 13,000 feet (-61 to 3.962 meters) Megabit Modem 400F, 500L, 600F, and 700F User Manual Appendix A: Specifications and Data...
  • Page 108: Compliance

    • T1.413 section 8.2 • FCC Part 15, Subpart B, Class A • CENELEC/ETSI (IEC 555 and 801) • CE (EN 55022 and EN 50082-1) • cUL (UL-1950) • CE (EN 60950) Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 109: Rate Vs. Reach

    Payload Rate vs Reach on 26 AWG (0.5 mm) with 4dB Margin in Low Noise Environment 10.000 1.000 0.100 0.010 Megabit Modem 400F, 500L, 600F, and 700F User Manual Reach in Kilofeet Reach in Kilofeet Appendix A: Specifications and Data Downstream...
  • Page 110: Hardware

    Hardware ARDWARE The following provides additional information about Megabit Modem 400F, 500L, 600F, and 700F such as the installation kit and modem connectors pinouts. Installation Kit The following items are included in the installation kit and are used to install the Megabit...
  • Page 111: Connector Pinouts

    MDI-X position for the 10/100BASE-T port. The connector for this interface is an RJ-45. page 18 for the location of this port. Megabit Modem 400F, 500L, 600F, and 700F User Manual page 18 for the location of this port.
  • Page 112 Hardware Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 113: Appendix B: Technical Assistance And Returns

    This chapter describes how to contact ADC for technical support. ECHNICAL UPPORT Technical support is available 24 hours a day, 7 days a week by contacting the ADC Wireline Systems Division Customer Service Engineering Group at one of the following numbers: •...
  • Page 114: Billing

    If products returned to ADC for advance replacement are not received by ADC within 30 calendar days of shipment of the replacement product or if no trouble is found (NTF) as determined by ADC, the Buyer will be responsible for payment of the cost of the replacement product.
  • Page 115: Returns

    To return equipment to ADC Wireline Systems Division: Locate the number of the purchase order under which the equipment was purchased. You will need to provide this number to ADC Wireline Systems Division Customer Service to obtain a return authorization.
  • Page 116 Number you received from Customer Service clearly on the outside of the carton and return ADC Wireline Systems Division 14352 Franklin Ave. Tustin, CA 92780-7013 Attention: RMA (Number) All shipments are to be returned prepaid. ADC will not accept any collect shipments. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 117: Appendix C: Configuration Worksheets

    IP addresses, IP address specified for each session by the service provider • for PPP system mode, Login Name and Login Password (specified for each session) Megabit Modem 400F, 500L, 600F and 700F User Manual ORKSHEETS NFORMATION Chapter 4...
  • Page 118: System Mode Worksheet

    • LLC • VC-MUX When Routing with RIP, select: • RIP direction • Version of RIP When Bridging, Enable Spanning Tree? (YES OR NO) Configuration Type __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ Megabit Modem 400F, 500L, 600F and 700F User Manual...
  • Page 119 CHAP Host Name Worksheet From Service Provider If PPP over ATM and using CHAP for authentication, enter CHAP host name for each session Megabit Modem 400F, 500L, 600F and 700F User Manual Configuration Information CHAP Host Name 1 __________________________ 2 __________________________ 3 __________________________...
  • Page 120: Wan Configuration Worksheet

    9 __________________________ 10 __________________________ 11 __________________________ 12 __________________________ 13 __________________________ 14 __________________________ 15 __________________________ 16 __________________________ Megabit Modem 400F, 500L, 600F and 700F User Manual 1 __________________________ 2 __________________________ 3 __________________________ 4 __________________________ 5 __________________________ 6 __________________________ 7 __________________________ 8 __________________________...
  • Page 121 WAN Configuration Worksheet - continued From Service Provider ATM Configuration (VPI/VCI for each session) Megabit Modem 400F, 500L, 600F and 700F User Manual Configuration Information 17 _________________________ 18 _________________________ 19 _________________________ 20 _________________________ 21 _________________________ 22 _________________________ 23 _________________________ 24 _________________________...
  • Page 122: Login Name / Login Password Worksheet

    2 ____________________________ 3 ____________________________ 4 ____________________________ 5 ____________________________ 6 ____________________________ 7 ____________________________ 8 ____________________________ 9 ____________________________ 10 ____________________________ 11 ____________________________ 12 ____________________________ 13 ____________________________ 14 ____________________________ 15 ____________________________ 16 ____________________________ Megabit Modem 400F, 500L, 600F and 700F User Manual Login Password...
  • Page 123 25 ____________________________ 26 ____________________________ 27 ____________________________ 28 ____________________________ 29 ____________________________ 30 ____________________________ 31 ____________________________ 32 ____________________________ Megabit Modem 400F, 500L, 600F and 700F User Manual Appendix C: Configuration Worksheets Login Information Login Name 17 ____________________________ 18 ____________________________ 19 ____________________________ 20 ____________________________...
  • Page 124: Fixed Ip Addresses Worksheet

    9___________ ___________ 10___________ ___________ 11___________ ___________ 12___________ ___________ 13___________ ___________ 14___________ ___________ 15___________ ___________ 16___________ ___________ Megabit Modem 400F, 500L, 600F and 700F User Manual ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________ ___________...
  • Page 125 Fixed IP Addresses Worksheet - continued Contact Service Provider Fixed IP Addresses (for each session) Not applicable if service provider dynamically assigns IP addresses. Megabit Modem 400F, 500L, 600F and 700F User Manual Appendix C: Configuration Worksheets Fixed IP Addresses Fixed IP Address 17__________ __________...
  • Page 126 Configuration Information Megabit Modem 400F, 500L, 600F and 700F User Manual...
  • Page 127: Appendix D: Glossary

    A fixed-length packet. Also, the unit of data transmission used in ATM. Each ATM cell contains a fixed-size frame (53 bytes) consisting of a five-byte header and a 48-byte payload. Megabit Modem 400F, 500L, 600F, and 700F User Manual LOSSARY...
  • Page 128 Cyclic Redundancy Check is a method used to verify the accuracy of data transmission. Discrete Multi-Tone is a modulation coding for an ADSL line. DMT is the modulation technology used for the Megabit Modem 400F, 500L, 600F, and 700F ADSL. downstream Communications from a service provider to a user.
  • Page 129 Request For Comment is a series of notes that contain surveys, measurements, ideas, techniques, and observations, as well as proposed and accepted TCP/IP protocol standards. RFCs are available on the Internet. Megabit Modem 400F, 500L, 600F, and 700F User Manual Appendix D: Glossary...
  • Page 130 The time during which two computers maintain a communication connection. An example is a connection configured between the Megabit Modem 400F, 500L, 600F, and 700F and the service provider. SNMP Simple Network Management Protocol is a protocol that specifies how to send information between a NMS and managed devices on a network.
  • Page 131 VPs are defined by a unique VPI value. Wide Area Network is a network consisting of nodes located across a large geographical area. Also, the connection between a service provider and Megabit 700F Modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual Appendix D: Glossary...
  • Page 132 Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 133 16 authentication security 87 back panel 17, 18 bridge/router 13, 87, 88, 107 description 88 bridging specifications 96 Megabit Modem 400F, 500L, 600F, and 700F User Manual cables connecting 18 installation 18 requirements 15 cell formats 95...
  • Page 134 100 phone service 13 requirements 9 installing the modem 15 attaching feet 16 cabling 18 flat-surface mounting 11 setting MDI/MDI-X switch 17 wall mounting 12 IP routing 90 See routing Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 135 84 attaching feet 16 configuration process 23 description 1 flat-surface mounting 11 Megabit Modem 400F, 500L, 600F, and 700F User Manual installation 15 obtaining IP Address automatically 24 overview 1 resetting 30 resetting to factory defaults default values 31...
  • Page 136 13, 87, 88, 107 routing specifications 96 static IP 90 saving a configuration 28, 59, 70 service ADSL 20 service provider configuration 13 requirements 13 sessions configuring 51, 63 site requirements 10 SNMP parameters Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 137 35 mode of operation Bridge/Router RFC 1483 48 PPP Over ATM 48 requirements 10 troubleshooting 84 Megabit Modem 400F, 500L, 600F, and 700F User Manual system menu factory default 31 reset unit 30 technical support 103 technical specifications 95...
  • Page 138 75 WAN statistics 76 configuration worksheet 110 wall mounting 12 interface specifications 95 viewing statistics 76 warranty 103 web browser configuration 25 worksheets 107 login 112, 113 VCI 110 VPI 110 Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 139 Index Megabit Modem 400F, 500L, 600F, and 700F User Manual...
  • Page 140 ADC DSL Systems, Inc. 14402 Franklin Avenue Tustin, CA 92780 Tel: 714.832.9922 Fax: 714.832.9924 For Technical Assistance: 800.638.0031 714.730.3222 ´+Q5¶5]¨ 1149215 Rev A...

This manual is also suitable for:

700f400f500l

Table of Contents

Save PDF