Page 1
Megabit Modem Megabit Modem Megabit Modem 400F, 500L, 600F, and 700F User Manual Version 3.2.X Catalog Number MMD4090I1 Issue 1...
Page 2
Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits, and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages.
Page 3
IP addresses used in this manual are for example only. You will acquire your own addresses from the service provider and your information services coordinator to configure the Megabit Modem 400F, 500L, 600F, and 700F. However, you will use the IP address specified in “Accessing the Modem Web Pages” on page 27 600F, and 700F from a Web browser.
Consult the dealer or an experienced radio/TV technician for help. This product meets all safety requirements per UL-1950 standard. This product meets all EMC and safety requirements per EN 300 386-2 and IEC 950 (EN60950). Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Chapter 4: Setting Up For Configuration ...23 Setting Up the PC To Configure the Modem ...24 Configuring a Web Browser... 25 Accessing the Modem Web Pages...27 Saving the Configuration...28 Megabit Modem 400F, 500L, 600F, and 700F User Manual Table of Contents...
Page 6
Configuring the WAN PPP Sessions ...53 Add a PPP over ATM WAN Session ...54 Modify a PPP over ATM WAN Session...57 Delete a PPP over ATM WAN Session ...57 Configuring the LAN...58 Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Page 7
Using the RS-232 Management Port... 80 Setting Up the PC to Request an IP Address...83 Troubleshooting...84 Chapter 10: Technical Reference ... 85 Transmission on the Wide Area Network ... 85 Megabit Modem 400F, 500L, 600F, and 700F User Manual Table of Contents...
Page 8
Compliance ...98 RFCs ...98 MIBs ...98 Rate vs. Reach...99 Hardware...100 Installation Kit ...100 Connector Pinouts ...101 Appendix B: Technical Assistance and Returns ...103 Technical Support ...103 World Wide Web ...103 viii Megabit Modem 400F, 500L, 600F, and 700F User Manual...
In addition, the LEDs on the modem front panel provide continual status at-a-glance for network and modem connections. The following sections list the Megabit Modem 400F, 500L, 600F, and 700F features and applications. Megabit Modem 400F, 500L, 600F, and 700F User Manual BOUT ®...
• contains an embedded SNMP agent • operates as a DHCP server • supports NAT (including NAPT) and DNS See the illustration on the next page for an application example. 400F Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Page 13
Chapter 1: About The Product Business Internet Access ADSL Internet 400F Megabit Modem 400F, 500L, 600F, and 700F User Manual...
RFC 2364 PPP over ATM (AAL5) • supports up to 8 sessions • contains an embedded SNMP agent • operates as a DHCP server • supports NAT (including NAPT) and DNS 500L Microfilter ADSL 500L Megabit Modem 400F, 500L, 600F, and 700F User Manual Internet...
EGABIT ODEM The Megabit Modem 600F is a high-performance ADSL modem designed for power users. It offers these features: • supports full-rate ADSL and G.lite • offers rates up to 7.552 Mbps downstream/928 kbps upstream for full rate • offers rates up to 1.5 Mbps downstream/512 kbps upstream for G.lite •...
• contains an embedded SNMP agent • operates as a DHCP server • supports NAT (including NAPT) and DNS See the illustration on the next page for an application example. 700F Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Page 17
Chapter 1: About The Product Large Business Internet Access ADSL Internet 700F Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Page 18
Megabit Modem 700F Megabit Modem 400F, 500L, 600F, and 700F User Manual...
This chapter identifies the preparations and prerequisites for installing the Megabit Modem 400F, 500L, 600F, and 700F. Before installing the modem, verify that: • The contents of the package are accurate as described on this page. • Your system meets the requirements for connecting to and configuring the modem (see “Requirements For Your System”...
Web browser installed such as Netscape • Ethernet hub (optional) EQUIREMENTS Before installing the Megabit Modem 400F, 500L, 600F, and 700F, you must: • select a location to install the modems as described in the section below • identify requirements to connect phones as described in the section...
Place the modems on a flat surface, such as on a table or in a rack. L IN Minimum 1-inch clearance Minimum 1-inch clearance Megabit Modem 400F, 500L, 600F, and 700F User Manual L IN L IN Chapter 2: What You Need To Start...
Observe the minimum dimensions between multiple modems (shown in the illustration) to ensure sufficient ventilation for heat dissipation Mount the Megabit Modem on a wall using the two screws included with the modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
PPP system mode, Login Name and Login Password (specified for each session) For more information about the configuration choices listed above, see Reference” on page Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 2: What You Need To Start ERVICE...
TFTP server. Power Cable The Megabit Modem 400F, 500L, 600F, and 700F are available with a variety of power supplies and power cords. When you order your modem, choose one of the following as the last number...
Adapter assembly connects to a DB-9 connector on the PC. Then, one RJ-45 connector installs in the adapter and the other connector into the console port on the modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual “Requirements For The Installation Site” Installation Kit...
Attaching the Feet TTACHING THE Attach each of the four adhesive-backed rubber feet to a footprint recess on the bottom of the modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
For connection to devices such as a PC MDI-X For connection to devices such as a hub 10/100BASE-T MDI-X Megabit Modem 400F, 500L, 600F, and 700F User Manual WITCH RS232 MGMT Chapter 3: Installing the Modem ADSL POWER...
PC, hub or other network device Wall jack with DMT ADSL service To power outlet Megabit Modem Switch 10/100BASE-T port RS-232 MGMT port (600F and 700F only) I - X Megabit Modem 400F, 500L, 600F, and 700F User Manual ADSL port Power connector...
Page 29
If you need pinouts for the ADSL and 10/100BASE-T connectors, see page 101. For information on how to use the RS-232 management port for maintenance, see “Using the RS-232 Management Port” on page Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 3: Installing the Modem “Connector Pinouts” on...
ADSL margin is at or above the value set by the service provider. ADSL margin is below the value set by the service provider. Telephone receiver is off hook. Telephone receiver is on hook. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
ONNECTING HONE The Megabit Modem 400F, 500L, 600F, and 700F modem provide full support for the ITU standard G.hs, G.dmt, and G.lite. In the traditional ADSL deployment, POTS splitters are required to separate data transmission from phone service. In this case, the service provider will supply you with a splitter.
Page 32
Connecting Phone Service Megabit Modem 400F, 500L, 600F, and 700F User Manual...
ETTING Set up a PC and a Web browser to configure the Megabit Modem 400F, 500L, 600F, and 700F. This chapter provides the set up procedures, then shows you how to access and navigate the Megabit Modem Web pages. The configuration process flow is shown below.
Network TCP/IP and skip to step 5. Otherwise, select The default LAN IP address is 192.168.0.1. Use an IP Megabit Modem 400F, 500L, 600F, and 700F User Manual ODEM icon. Obtain an IP Specify an IP address...
Open your Web browser. Click Edit Preferences From Category, select From Category, select Click to close the Preferences window. Megabit Modem 400F, 500L, 600F, and 700F User Manual ROWSER to open the Preferences dialog. Advanced , click Cache, then select Advanced...
Page 36
Internet Options dialog. section of the dialog, click , then click tab, then click LAN Settings to open the LAN Settings dialog. Use a proxy server Megabit Modem 400F, 500L, 600F, and 700F User Manual Settings box.
If the Megabit Modem is in “Bridging/Routing” mode, it displays this page: Megabit Modem 400F, 500L, 600F, and 700F User Manual ODEM AGES Location Bar field of the Web browser (as shown below), then press Location Bar http://192.168.0.1/index.htm...
• reset the modem to restore the factory default values on Apply . However, there are other Menu system general general general general page 29 page 30 page 31 Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Locate Apply at the bottom of the dialog. Click to open the Apply confirmation dialog. Click to reset the modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 4: Setting Up For Configuration the changes are automatically saved...
From the system menu, click Click Reset Unit. Click Proceed to reset the modem. general to open the General System window. Megabit Modem 400F, 500L, 600F, and 700F User Manual page 28...
When you click Proceed to return to factory default values, the modem automatically resets. Click Proceed to return to factory default values. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 4: Setting Up For Configuration page 32 general to open the General System window.
Page 42
Primary DNS Enabled Gateway Dynamic Static NAT Entries (private, proxy, and remote) 0.0.0.0 IP Addresses Ports blank field Protocol 0.0.0.0 Megabit Modem 400F, 500L, 600F, and 700F User Manual Default Value Not enabled 0.0.0.0 255.255.255.0 public public private 192.168.0.1 255.255.255.0 Enabled 192.168.0.2...
Page 43
Static Mac Address Entry MAC Address Source Port Dest Port Static Route Entry (IP Address, IP Network Mask, Gateway IP Address) Megabit Modem 400F, 500L, 600F, and 700F User Manual Default Value Parameter Bridge/Router RFC 1483 Not selected Spanning Tree blank field...
Page 44
Saving the Configuration Megabit Modem 400F, 500L, 600F, and 700F User Manual...
48 either PPP over ATM or 1483 Bridging/Routing (for Megabit Modem 700F only) Unless specified otherwise, configuration parameters shown in this section are for example only. Megabit Modem 400F, 500L, 600F, and 700F User Manual YSTEM page 36 page 38 for sessions between the modem and the service provider;...
This may or may not be required depending on the TFTP server configuration. (Example: c:\download\) File Name The full name of the updated software (example: tiger.bin) ARAMETERS Megabit Modem 400F, 500L, 600F, and 700F User Manual page 77 for procedures on...
Page 47
“tiger.bin” has been placed directly inside the shared directory (not in a subdirectory of the shared directory). Therefore, the File Path should be left blank. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 5: Configuring System Settings of the updated software file.
The authentication string for viewing the modem statistics and changing parameters. The SNMP management station must have the same string in its configuration. The default is private. page 39 Megabit Modem 400F, 500L, 600F, and 700F User Manual and are case sensitive. If you...
Page 49
, and read-write community string set to Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 5: Configuring System Settings trapit , read-only community string set to...
From the system menu, click NAT E NTRIES page 87 static NAT table to open the Static NAT Table window. Megabit Modem 400F, 500L, 600F, and 700F User Manual Static NAT for more information on NAT...
Page 51
Click to accept the changes or Megabit Modem 400F, 500L, 600F, and 700F User Manual of the device on the LAN side of the modem. of the device on the LAN side of the modem. that is mapped to the Private IP Address.
Select of the address to be changed. MAC E TATIC NTRIES static MAC table to open the Static MAC Table window. static MAC table to open the Static MAC Table window. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Click Select of the address to be deleted. Click Delete to remove the selected address. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 5: Configuring System Settings static MAC table to open the Static MAC Table window.
Click to change the existing data to the list. TATIC OUTES static route table to open the Static Route Table window. to open the Static Route Table window. static route table Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Click Select of the static route to be deleted. Click Delete to remove the selected route. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 5: Configuring System Settings static route table to open the Static Route Table window.
Example: The illustration above shows the modem configuration to allow only the station with the IP address 192.168.0.3 to access the modem on the same LAN. YSTEM ECURITY general to open the General System window. Megabit Modem 400F, 500L, 600F, and 700F User Manual 0.0.0.0 in the...
You can change the Admin IP Address for the 600F and 700F by physically connecting to the RS-232 MGMT port. RS-232 MGMT Port The RS-232 MGMT Port allows access to several parameters such as the LAN IP settings, Admin IP Address, and modem reset.
The Megabit Modem 400F operates only in Bridge/Router RFC 1483 mode, while the Megabit Modem 500L and 600F operate only in PPP over ATM mode. This section provides procedures to select the system mode. Then, use the section “Saving the Configuration”...
Page 59
Click Apply At the Proceed message, click Click reset unit to reset the modem and activate the changes. At the System Reset message, click Proceed Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 5: Configuring System Settings...
Page 60
Selecting the System Mode of Operation Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Configuring the WAN PPP Sessions Configuring the LAN Assigning LAN Users to PPP Sessions Activating and Deactivating Sessions For these sessions, PPP runs over ATM virtual circuits (VCs). Megabit Modem 400F, 500L, 600F, and 700F User Manual PPP S ESSIONS Go to page:...
Select PPP Over ATM as the of Operation Click Apply , then reset the modem. ARAMETERS How IP Address Acquired Dynamic Dynamic Fixed Fixed Fixed PPP M (700F O Mode Megabit Modem 400F, 500L, 600F, and 700F User Manual...
• 32 sessions for a 700F Access the WAN Connections Megabit Modem 400F, 500L, 600F, and 700F User Manual WAN PPP S page, you configure parameters that set up communication between page and use the following table for reference. Chapter 6: Configuring PPP Sessions...
Add a PPP over ATM WAN Session You add a PPP WAN session in the reference table and procedure to set up a session. PPP Over ATM WAN Configuration Megabit Modem 400F, 500L, 600F, and 700F User Manual window. Use the following...
Page 65
If enabled, the session is active and is ready to establish the PPP link. If disabled, the session is not active. Address Assignment Determines whether the session IP address is assigned by the service provider (Dynamic) or entered by the user (Fixed). Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 6: Configuring PPP Sessions...
Page 66
Click Refresh to update the connections window. to display the PPP Over ATM WAN Configuration cancel to cancel the set up of the session. Megabit Modem 400F, 500L, 600F, and 700F User Manual page.
Click Refresh to update the WAN Connections window. Megabit Modem 400F, 500L, 600F, and 700F User Manual Port 1-32 to display the PPP Over ATM WAN Configuration page 55 connections to open the WAN Connections window.
Primary DNS IP address of the primary Domain Name System (DNS) device that translates names into IP addresses. Default Gateway Default router set to the IP address of the LAN port. Megabit Modem 400F, 500L, 600F, and 700F User Manual general...
Although you have submitted your new system settings, the parameters are not permanent until you write them to NVRAM. See to save to NVRAM. Megabit Modem 400F, 500L, 600F, and 700F User Manual Net Mask “Saving the Configuration” on page 28...
500L. In addition, you can map 64 users to the sessions you configure for the 600F and 700F. For example, you could map two users to 32 configured sessions, 64 users to one configured session, or any combination you choose, up to a maximum of 64 users mapped to all the sessions you configure.
Select the user assignment to be deleted, then click the Click Delete to remove the selected user assignment. Megabit Modem 400F, 500L, 600F, and 700F User Manual user assignment to open the WAN User Assignment window. Select Chapter 6: Configuring PPP Sessions...
To activate the session, place a checkmark in the Session Enable To deactivate the session, clear the checkmark. Click to accept the changes. EACTIVATING connections box by clicking in it. Megabit Modem 400F, 500L, 600F, and 700F User Manual ESSIONS...
Setting Up the Bridging/Routing Mode (700F Only) Configuring the WAN Bridging/Routing Sessions Configuring the LAN Activating and Deactivating Sessions For these sessions, PPP runs over ATM virtual circuits (VCs). Megabit Modem 400F, 500L, 600F, and 700F User Manual ONFIGURING OUTING ESSIONS Go to page:...
To have all sessions, up to 32, as Bridging/Routing mode of operation, do the following: From the system menu, select general Select Bridge/Router RFC1483 Mode of Operation Click Apply , then reset the modem. RIDGING OUTING Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Displays the connection state. Up - Session is up. Down - Session is down. Connecting - Session is setting up. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 7: Configuring Bridging/Routing Sessions WAN B RIDGING page, you configure parameters that set up communication between...
The IP Net Mask address of the modem's WAN port. RIP Direction The direction the RIP routing information flows. RIP Version The version of the RIP protocol. WAN Port Configuration window. Use the Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Page 77
Click to create the session or click Click Refresh to update the connections window. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 7: Configuring Bridging/Routing Sessions to display the WAN Port Configuration cancel to cancel the set up of the session.
66 connections to open the WAN Connections window. edit to open the WAN Port Configuration Cancel Megabit Modem 400F, 500L, 600F, and 700F User Manual page for that for a description of parameters. page. to cancel any changes you made...
The function of routing packets based on layer 3 headers. Enable Enables/Disables routing. RIP Direction The direction the RIP routing information flows. RIP Version The version of the RIP protocol. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 7: Configuring Bridging/Routing Sessions general...
Although you have submitted your new system settings, the parameters are not permanent until you write them to NVRAM. See to save to NVRAM. Net Mask “Saving the Configuration” on page 28 Megabit Modem 400F, 500L, 600F, and 700F User Manual when you want...
To activate the session, place a checkmark in the Session Enable To deactivate the session, clear the checkmark. Click to accept the changes. Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 7: Configuring Bridging/Routing Sessions EACTIVATING connections box by clicking in it. ESSIONS...
Page 82
Activating and Deactivating Sessions Megabit Modem 400F, 500L, 600F, and 700F User Manual...
(“Viewing Network Statistics” on page ADSL S IEWING The Megabit Modem 400F, 500L, 600F, and 700F displays the status of the ADSL link. Resetting ADSL will close off the ADSL loop connection between the modem and the service provider. Active connections will disconnect.
Page 84
Shows the rate of data transmission in kilobits per second (kbps). From the adsl menu, click Monitor the ADSL Status. Click Refresh to update the statistics or status to open the ADSL Status window. Clear to clear the statistics. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
IEWING ETWORK The Megabit Modem 400F, 500L, 600F, and 700F display status for the LAN and WAN links. From the Main Menu , select LAN Statistics The Megabit Modem 400F, 500L, 600F, and 700F displays status for the LAN. View the following LAN information:...
Viewing Network Statistics WAN Statistics The Megabit Modem 400F, 500L, 600F, and 700F displays status for the WAN. View the following WAN information: Information Description Rx Packets The total number of packets received at the WAN interface. Tx Packets The total number of packets transmitted out the WAN interface.
“Updating Software” on page 77 Megabit Modem 400F, 500L, 600F, and 700F. Through the RS-232 MGMT port on the Megabit Modem 600F and 700F, you can change the modem LAN port IP address and network mask, the default gateway IP address, and the IP...
Page 88
TFTP server (if necessary). Enter the File Name of the updated software file. page to configure the TFTP parameters. general to open the General System window. (subnet mask) for the TFTP server. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Page 89
Click Proceed to confirm the file transfer process. Wait for the file to download. 10 Click to restart the modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual to begin the file transfer. Chapter 9: Maintenance and Troubleshooting...
Connect the modem to a PC as shown below. PC, hub or other network device Wall jack with DMT ADSL service Switch 10/100BASE-T port RS-232 MGMT port (600F and 700F only) ADSL port I - X Megabit Modem 400F, 500L, 600F, and 700F User Manual Power connector...
Page 91
(1)Enter IP address (2)Enter IP network mask (3)Enter default gateway IP address (4)Enter IP Admin address (5)Reset modem (6)Change password (7)Logout > Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 9: Maintenance and Troubleshooting 3.0.0(1) 3.2.0 192.168.0.1 255.255.255.0 0.0.0.0...
Page 92
IP address for a device on the LAN that will manage the modem. Type to reset the modem after you change the LAN IP address and the LAN IP network mask. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Obtain an IP address automatically Click to close the TCP/IP Properties window. Click to close the Network window. Click to restart the computer. Megabit Modem 400F, 500L, 600F, and 700F User Manual EQUEST AN window by clicking Start Settings icon. TCP/IP...
LEDs are not on on the WAN ADSL port. If, the SYNC LED is not on, contact your service provider. “Setting Up the PC To Configure in this table. Megabit Modem 400F, 500L, 600F, and 700F User Manual “PC or hub not...
DMT ADSL provides rate-adaptive transmission that allows the service provider to deliver you the best transmission rate determined by distance and line conditions. Megabit Modem 400F, 500L, 600F, and 700F User Manual EFERENCE ETWORK...
The VPI and VCI provide the virtual connection between the modem and the service provider. The VPI identifies the Virtual Path (VP) that transports ATM cells in a Virtual Channel (VC). The Megabit Modem 400F, 500L, 600F, and 700F has 32 VCs in the VP, which provides the 32 sessions.
IP address ranges can benefit from this operation, as the private IP addresses will remain the same when the public IP addresses are reassigned. Megabit Modem 400F, 500L, 600F, and 700F User Manual NCAPSULATION Chapter 10: Technical Reference...
An example of the active topology is shown on algorithm partitions out the bridge from LAN A to LAN B, and creates the link from ENET2 to Bridge 5. page 89. In the example, the spanning tree Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Page 99
Spanning Tree to eliminate loops. Bridge 1 ENET 1 Bridge 4 Using Spanning Tree Protocol Bridge 1 ENET 1 Bridge 4 Megabit Modem 400F, 500L, 600F, and 700F User Manual Bridge 2 Bridge 3 Bridge 5 ENET 3 Loop-free Topology LAN A Bridge 2...
IP). VC-MUX allows only one protocol to run over the VC. The type of protocol must be negotiated between the modem and the service provider prior to the transmission. Because there is only one protocol allowed, the header is not required. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
The Internet Engineering Task Force (IETF) specifies standard MIBs for certain types of devices, ensuring any NMS can manage them. Additionally, vendors can issue proprietary MIBs for their devices to fit specific needs. Megabit Modem 400F, 500L, 600F, and 700F User Manual ROTOCOLS Chapter 10: Technical Reference...
Spanning Tree, and transparent bridging groups. The Spanning Tree MIB can only be accessed if the Spanning Tree protocol is enabled. • ADSL MIB • ATM MIB • ADC Agent MIB • ADC Tiger MIB Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Internet. Once you have selected and installed the TFTP server software, configure it to share a directory containing the binary files. To configure the Megabit Modem to access the TFTP server, see Megabit Modem 400F, 500L, 600F, and 700F User Manual Chapter 10: Technical Reference Chapter 9 on page...
Page 104
TFTP Server Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Signal Format Connector ATM Adaptation Layer ATM Layer Cell Format Virtual Circuit type Maximum Virtual Circuits Megabit Modem 400F, 500L, 600F, and 700F User Manual PECIFICATIONS ADSL (Asymmetric Digital Subscriber Line) 7.552 Mbps 928 kbps 64 kbps 32 kbps increments...
Implements a transparent learning bridge with a bridging table of 1024 entries. Learning Encapsulation Supports Logical Link Control (LLC) or VC-based multiplexing (RFC 1483). Spanning Tree Provides Spanning Tree support per IEEE 802.1d. Routing Bridging Megabit Modem 400F, 500L, 600F, and 700F User Manual...
0.3 Amps NVIRONMENTAL Temperature 32° to 122 °F (0° to 50°C) Relative Humidity up to 95% non-condensing Altitude between -200 and 13,000 feet (-61 to 3.962 meters) Megabit Modem 400F, 500L, 600F, and 700F User Manual Appendix A: Specifications and Data...
• T1.413 section 8.2 • FCC Part 15, Subpart B, Class A • CENELEC/ETSI (IEC 555 and 801) • CE (EN 55022 and EN 50082-1) • cUL (UL-1950) • CE (EN 60950) Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Payload Rate vs Reach on 26 AWG (0.5 mm) with 4dB Margin in Low Noise Environment 10.000 1.000 0.100 0.010 Megabit Modem 400F, 500L, 600F, and 700F User Manual Reach in Kilofeet Reach in Kilofeet Appendix A: Specifications and Data Downstream...
Hardware ARDWARE The following provides additional information about Megabit Modem 400F, 500L, 600F, and 700F such as the installation kit and modem connectors pinouts. Installation Kit The following items are included in the installation kit and are used to install the Megabit...
MDI-X position for the 10/100BASE-T port. The connector for this interface is an RJ-45. page 18 for the location of this port. Megabit Modem 400F, 500L, 600F, and 700F User Manual page 18 for the location of this port.
Page 112
Hardware Megabit Modem 400F, 500L, 600F, and 700F User Manual...
This chapter describes how to contact ADC for technical support. ECHNICAL UPPORT Technical support is available 24 hours a day, 7 days a week by contacting the ADC Wireline Systems Division Customer Service Engineering Group at one of the following numbers: •...
If products returned to ADC for advance replacement are not received by ADC within 30 calendar days of shipment of the replacement product or if no trouble is found (NTF) as determined by ADC, the Buyer will be responsible for payment of the cost of the replacement product.
To return equipment to ADC Wireline Systems Division: Locate the number of the purchase order under which the equipment was purchased. You will need to provide this number to ADC Wireline Systems Division Customer Service to obtain a return authorization.
Page 116
Number you received from Customer Service clearly on the outside of the carton and return ADC Wireline Systems Division 14352 Franklin Ave. Tustin, CA 92780-7013 Attention: RMA (Number) All shipments are to be returned prepaid. ADC will not accept any collect shipments. Megabit Modem 400F, 500L, 600F, and 700F User Manual...
IP addresses, IP address specified for each session by the service provider • for PPP system mode, Login Name and Login Password (specified for each session) Megabit Modem 400F, 500L, 600F and 700F User Manual ORKSHEETS NFORMATION Chapter 4...
• LLC • VC-MUX When Routing with RIP, select: • RIP direction • Version of RIP When Bridging, Enable Spanning Tree? (YES OR NO) Configuration Type __________________________ __________________________ __________________________ __________________________ __________________________ __________________________ Megabit Modem 400F, 500L, 600F and 700F User Manual...
Page 119
CHAP Host Name Worksheet From Service Provider If PPP over ATM and using CHAP for authentication, enter CHAP host name for each session Megabit Modem 400F, 500L, 600F and 700F User Manual Configuration Information CHAP Host Name 1 __________________________ 2 __________________________ 3 __________________________...
Page 121
WAN Configuration Worksheet - continued From Service Provider ATM Configuration (VPI/VCI for each session) Megabit Modem 400F, 500L, 600F and 700F User Manual Configuration Information 17 _________________________ 18 _________________________ 19 _________________________ 20 _________________________ 21 _________________________ 22 _________________________ 23 _________________________ 24 _________________________...
Page 125
Fixed IP Addresses Worksheet - continued Contact Service Provider Fixed IP Addresses (for each session) Not applicable if service provider dynamically assigns IP addresses. Megabit Modem 400F, 500L, 600F and 700F User Manual Appendix C: Configuration Worksheets Fixed IP Addresses Fixed IP Address 17__________ __________...
Page 126
Configuration Information Megabit Modem 400F, 500L, 600F and 700F User Manual...
A fixed-length packet. Also, the unit of data transmission used in ATM. Each ATM cell contains a fixed-size frame (53 bytes) consisting of a five-byte header and a 48-byte payload. Megabit Modem 400F, 500L, 600F, and 700F User Manual LOSSARY...
Page 128
Cyclic Redundancy Check is a method used to verify the accuracy of data transmission. Discrete Multi-Tone is a modulation coding for an ADSL line. DMT is the modulation technology used for the Megabit Modem 400F, 500L, 600F, and 700F ADSL. downstream Communications from a service provider to a user.
Page 129
Request For Comment is a series of notes that contain surveys, measurements, ideas, techniques, and observations, as well as proposed and accepted TCP/IP protocol standards. RFCs are available on the Internet. Megabit Modem 400F, 500L, 600F, and 700F User Manual Appendix D: Glossary...
Page 130
The time during which two computers maintain a communication connection. An example is a connection configured between the Megabit Modem 400F, 500L, 600F, and 700F and the service provider. SNMP Simple Network Management Protocol is a protocol that specifies how to send information between a NMS and managed devices on a network.
Page 131
VPs are defined by a unique VPI value. Wide Area Network is a network consisting of nodes located across a large geographical area. Also, the connection between a service provider and Megabit 700F Modem. Megabit Modem 400F, 500L, 600F, and 700F User Manual Appendix D: Glossary...
Page 132
Megabit Modem 400F, 500L, 600F, and 700F User Manual...
Need help?
Do you have a question about the 600F and is the answer not in the manual?
Questions and answers