Siemens SIMATIC ET 200SP F-TM Equipment Manual page 100

Hide thumbs Also See for SIMATIC ET 200SP F-TM:
Table of Contents

Advertisement

Article number
Potential separation
Potential separation channels
between the channels and backplane bus
Isolation
Isolation tested with
Overvoltage category
Degree of pollution
Degree and class of protection
IP degree of protection
Standards, approvals, certificates
CE mark
cULus
Standard for EMC according to EN 61800-3
Standard for drive acc. to EN 61800-5-1
Standard for drive acc. to EN 61800-5-2
Highest safety class achievable in safety mode
Performance level according to ISO 13849-
1
SIL according to DIN EN 61800-5-2
Ambient conditions
Pollution degree during storage and transport
Ambient temperature during operation
horizontal installation, min.
horizontal installation, max.
vertical installation, min.
vertical installation, max.
Ambient temperature during stor-
age/transportation
Storage, min.
Storage, max.
Altitude during operation relating to sea level
Installation altitude above sea level, max.
Cables
Cable length for motor, shielded, max.
F-TM ServoDrive
Equipment Manual, 02/2020, A5E47579503-AA
11.1 Technical specifications of the ET 200SP F-TM ServoDrive
6BK1136-6AB00-0BU0
Yes
707 V DC/1 min, type test (between backplane
bus and functional ground)
2
2 according to EN 61800-5-1
IP20
Yes
No
Yes, according to second environment Category
C2 acc. EN 61800-3
Yes
Yes
Category 3, performance level d, according to EN
ISO 13849-1:2015
SIL 2 according to EN 61800-5-2:2017
2
-30 °C; No condensation, splash water, icing, salt
spray or oil mist permitted.
60 °C; No condensation, splash water, icing, salt
spray or oil mist permitted. Note the derating
data!
-30 °C; No condensation, splash water, icing, salt
spray or oil mist permitted.
50 °C
-40 °C
70 °C
3 000 m
10 m