System Fan Indication; System Temperature Indication; Normal System Startup Led Indications; Scopia 400 Chassis Power Supply - RADVision SCOPIA 400 Platform Manual

Hide thumbs Also See for SCOPIA 400:
Table of Contents

Advertisement

S
F
YSTEM
AN
I
NDICATION
S
T
YSTEM
EMPERATURE
I
NDICATION
N
S
ORMAL
YSTEM
S
LED
TARTUP
I
NDICATIONS
SCOPIA 400
C
P
HASSIS
OWER
S
UPPLY
The FAN LED functions as follows:
Illuminates green to indicate that the fans are operating properly.
Illuminates red when that a malfunction occurs in one or more fans.
The TEMP LED functions as follows:
Illuminates green to indicate normal operation.
Illuminates red when the operating temperature inside the chassis
rises above the High threshold value set at System > High in the web
user interface of the MCU and Gateway.
Blinks green to indicate an inaccurate temperature reading. If the
LED blinks green for a few seconds and then illuminates
continuously, no action is necessary. If the LED blinks green
continuously, contact
This section describes the normal LED indications that you should see when the
system starts up.
At startup, the normal system monitor LED indications are as follows:
The POWER LED indicator lights green and remains green.
The ALARM, FAN and TEMP LED indicators flash twice,
alternating between red and green. When the platform initialization is
complete, the LED indicators remain green.
The rear panel of the SCOPIA 400 chassis contains dual power supply units,
each with a power switch, an AC mains power connector and a safety fuse. The
two PSUs use current sharing to provide redundancy—if one PSU fails, the
second PSU can handle the operational load of the chassis until the failed unit is
replaced. The PSUs are located to the left of the chassis rear panel., as shown in
Figure
1-2.
Each power supply has one LED indicator—green to indicate normal operation,
red to indicate a malfunction.
In normal operation, both PSUs display a lit green LED, and the front panel
system monitoring POWER LED lights green.
Note
To enable PSU redundancy, connect both power inlets to a power source.
If you connect only one power cable, the POWER LED on the chassis front panel
and the LED indicator on the PSU not in use will both light red.

SCOPIA 400 Chassis Power Supply

Customer Support.
RADVISION
SCOPIA 400 Platform Chassis Overview
3

Advertisement

Table of Contents
loading

Table of Contents