4.

Maintenance/Expansion

Hot Swap/Hot Expansion

"Hot swap" allows components to be replaced, or allows the firmware to be updated while the system is running.
"Hot expansion" allows components to be added while the system is running.

Hot Swap/Hot Expansion (ETERNUS AF250 S2)

The table below shows whether hot swap or hot expansion for components of the ETERNUS AF250 S2 is possible.

Table 47 Hot Swap and Hot Expansion Availability for Components (ETERNUS AF250 S2)

Component
Controller enclosure (CE)
Controller module (CM)
System memory
BBU
BUD
Controller firmware
Host interface (FC-CA)
Host interface (10G iSCSI-CA)
Power supply unit (PSU)
SSD
Operation panel (PANEL)
Disk firmware
Drive enclosure (DE)
Power supply unit (PSU)
SSD
Operation panel (PANEL)
I/O module (IOM)
Disk firmware
¡: Allowed / ´: Not allowed (cold swap is possible) / —: Not applicable
*1: Mid Plane. This is a board that is located between the front (drive side) and rear (controller (CM) side) of
the ETERNUS AF.
*2: All of the host interfaces on the CM that will have maintenance or expansion performed go offline. When a
multipath configuration is used, switch to the host paths of the CM that will not have maintenance per-
formed to continue operation.
*3: Depending on the changes in the firmware, this function may require I/Os to be temporarily stopped.
*4: Operation can be continued during a failure. The status of the ETERNUS AF can be monitored via ETERNUS
Web GUI or ETERNUS CLI.
Hot swap
´
¡ (*2)
¡ (*2)
¡ (*2)
¡ (*2)
¡ (*2) (*3)
¡ (*2)
¡ (*2)
¡
¡
´ (*4)
¡ (*3)
¡
¡
¡
´ (*4)
¡
¡ (*3)
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Design Guide (Basic)
Copyright 2019 FUJITSU LIMITED
Hot expansion
Remarks
Replace the controller enclosure (CE) when
the MP (*1) fails.
¡ (*2)
¡ (*2)
¡
Replace the drive enclosure (DE) when the
¡
MP (*1) fails.
¡
160