Audit Log; Figure 42 Audit Log - Fujitsu ETERNUS AF250 Design Manual

All-flash arrays
Hide thumbs Also See for ETERNUS AF250:
Table of Contents

Advertisement

1.
Function
User Access Management

Audit Log

The ETERNUS AF can send information such as access records by the administrator and setting changes as audit
logs to the Syslog servers.
Audit logs are audit trail information that record operations that are executed for the ETERNUS AF and the re-
sponse from the system. This information is required for auditing.
The audit log function enables monitoring of all operations and any unauthorized access that may affect the
system.
Syslog protocols (RFC3164 and RFC5424) are supported for audit logs.
Information that is to be sent is not saved in the ETERNUS AF and the Syslog protocols are used to send out the
information. Two Syslog servers can be set as the destination servers in addition to the Syslog server that is used
for event notification.

Figure 42 Audit Log

Log in
Change settings
Log out
System administrator
ETERNUS AF
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Design Guide (Basic)
Copyright 2019 FUJITSU LIMITED
Information such as
the storage system name,
the user/role,
the process time,
the process details,
and the process results
Audit log
Syslog server
75