Figure 98 Power Supply Control Using a Power Synchronized Unit (When Connecting Three or More Servers)

Turns on: 1
Turns off: 2
UPS unit for
Server#1
UPS unit for
Server#0
Powering on sequence
1
Power on of all the server UPS units
2
Server startup
The server OS startup is suspended until the ETERNUS AF startup is complete (*1).
3
Issuance of command to turn on the ETERNUS AF from the power synchronized unit
4
ETERNUS AF startup
*1: The server must be set to suspend server OS startup until the ETERNUS AF startup is complete.