Function
Backup (Advanced Copy)
To suspend a Cascade Copy where session 1 is performed before session 2 and session 2 is an EC or REC
session, perform the Suspend command after the physical copy for copy session 1 is complete.
A Cascade Copy can be performed when the copy type for copy session 1 is XCOPY or ODX. The copy destina-
tion area for XCOPY or ODX and the copy source area for copy session 2 do not have to be completely identi-
cal. For example, a Cascade Copy can be performed when the copy source area for copy session 2 is only
part of the copy destination area for copy session 1.
XCOPY or ODX cannot be set as the copy type for copy session 2 in a Cascade Copy.
For more details on XCOPY and ODX, refer to
To acquire valid backup data in the copy destination for copy session 2, a physical copy must be completed
or suspended in all of the copy sessions that configure the Cascade Copy. Check the copy status for copy
sessions 1 and 2 when using the backup data.
However, if a Cascade Copy performs session 1 before session 2, and copy session 1 is an OPC or QuickOPC
session and copy session 2 is an OPC, QuickOPC, SnapOPC, or SnapOPC+ session, the data in the copy desti-
nation for copy session 2 is available even during a physical copy.
If copy session 1 is an EC or REC session and copy session 2 is an OPC, QuickOPC, SnapOPC, or SnapOPC+
session, setting copy session 2 after setting copy session 1 to an equivalent or suspended state is recom-
mended.
When stopping an OPC or QuickOPC session for copy session 1 during a physical copy, stop copy session 2 in
advance if copy session 2 is an OPC, QuickOPC, SnapOPC, or SnapOPC+ session.
If copy session 2 is an EC or REC session, copy session 2 does not transition to an equivalent state until the
physical copy for copy session 1 is complete. For an EC session, a copy session cannot be suspended until
the session transitions to an equivalent state.
If a Cascade Copy performs session 1 before session 2, and copy session 1 is an OPC or QuickOPC session, the
logical data in the intermediate volume when copy session 2 is started (the copy destination volume for
copy session 1) is copied to the copy destination volume for copy session 2. A logical data copy is shown
below.
OPC / QuickOPC
: Copy session 1
: Copy session 2
OPC / QuickOPC /
SnapOPC /
SnapOPC+ / EC / REC
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays Design Guide (Basic)
Copyright 2019 FUJITSU LIMITED
"Server Linkage Functions" (page
99
112).
P3AG-1822-09ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus af250 s2

Table of Contents