Internal cabinet control panel
Hide thumbs Also See for eView BOX:
Table of Contents

Advertisement

Connected cards
Information is shown in tabular form. Each column represents
a card, for which the following information is shown:
Cfg: card name at time of configuration
PwOn: card name - shows which card was recognized
at time of power-on.
Real: card name recognized now
Card icon: identifies card type. May assume the following
shapes:
1. Slot with configured card.
2. Slot with non-configured card.
3. Slot not managed.
1
2
Flag: shows slot status with colored code. Meanings:
- Green: Slot with card correctly configured.
- Yellow: card configured but not inserted in slot.
- Blue: card added to powered-on terminal.
- Violet: Error. At power-on, the card is in a non-
configured slot or a slot configured for a different card.
- Red: card malfunctioned during operation (red with
white point at center = card terminal shorted).
- Gray: slot not managed / invalid slot.
Detailed status of card
Click the icon of one of the listed cards: details of the status
of its terminals are shown in the bottom box.
For example, in the figure the first device ([U16] - 1) has been
clicked.
The names of the variables are listed on the left; their values
are shown on the right.
These signals repeat any signals present on the card.
The tabs under the box have the following meaning:
DIN: digital inputs.
DOU: digital outputs.
AIN: analog inputs.
AOU: analog outputs.
T_C: analog temperature inputs.
D_A: physically digital inputs and outputs managed as
analog by the program.
INF: card information.
If a card does not have even one terminal of a defined
category, its tab will be displayed without label.
34

ICT

Click the ICT button on the lower navigation bar to access
ICT diagnostics.
ICT (Industrial Central Terminal) means management of
3
data exchange by the Gefran target to and from remote
devices, which may be instruments and/or PLCs of other
manufacturers, via dedicated protocols.
To date, the managed and diagnosed protocols are:
Ict Diagnostics Interface
The main interface of the Gefran Ict Diagnostics tool is:
The component is divided into 2 Zones:
The main window lists the configured devices.
Several columns are shown, with the following content:
Status: operating status:
Modbus TCP
Modbus RTU
a list of ICT devices described in the system.
a button that lets you access advanced information on
the network.
"---" Slave not previously communicated with;
"ERR" Slave with which a communication error has
occurred;
"OK" Slave with which all (at least one)
communication(s) were/was successful;
"L-E" Line Error. Used only for Slaves in TCP
positioned on nodes not connected to the network
(for example, disconnected network cable).
ID: Unique device identifier (as inserted in HW
configurator). Useful for pointing at device in PLC code.
Protocol & Description: string describing the device.
80949_MAN_eView BOX_05-2019_ENG