Check version files
Press the Check version files button to activate the check
of the installed version and of the individual softwares/
components it includes. The following page appears:
The lines change from purple to green as the checksum is
checked.
If the checksum is correct, the line stays green and the file
version is shown.
If the checksum is wrong, the line turns red and the message
"wrong MD5 checksum found!" appears next to the version.
Click the show MD5 checksum box to see the checksum
value immediately
Press Home to return to the main menu. Press <<-back to
return to the previous menu.
80949_MAN_eView BOX_05-2019_ENG

Temperature

Gives information on the temperatures measured in the
eView.
Limits shows the temperature limits for normal operation
Istant. shows the current temperature.
For every overtemperature interval, the table shows the last
measured value and the date and time the overtemperature
occurred.
Min peak and Max peak show the minimum and maximum
temperature measured, with the date and time of
measurement.
Press Home to return to the main menu.
Press the magnifying glass icon on the table to access the
historical file for that temperature interval.
You can go from one temperature interval to another by
pressing the relative tab.
Press Home to return to the main menu. Press <<-back to
return to the previous page.